Safety instructions
Transport and installation
099-002060-EW501
19.10.2015
13
2.4.1
Ambient conditions
CAUTION
Installation location
The machine may only be placed and operated on a suitable, load-bearing and even
surface (according to IP 34s in case of outside operation as well)!
• Ensure the machine is operated on an even, anti-slip floor and provide sufficient lighting of
the work area.
• Safe operation of the machine must be guaranteed at all times!
CAUTION
Equipment damage due to dirt accumulation!
Unusually high quantities of dust, acid, corrosive gases or substances may damage the
equipment.
• Avoid high volumes of smoke, vapour, oil vapour and grinding dust!
• Avoid ambient air containing salt (sea air)!
Non-permissible ambient conditions!
Insufficient ventilation results in a reduction in performance and equipment damage.
• Observe the ambient conditions!
• Keep the cooling air inlet and outlet clear!
• Observe the minimum distance of 0.5 m from obstacles!
2.4.1.1 In operation
Temperature range of the ambient air:
• -25 °C to +40 °C
Relative air humidity:
• Up to 50% at 40 °C
• Up to 90% at 20 °C
2.4.1.2 Transport and storage
Storage in an enclosed space, temperature range of the ambient air:
• -30 °C to +70 °C
Relative air humidity
• Up to 90% at 20 °C