Design and function
Special parameters (advanced settings)
86
099-005403-EW501
10.2.2022
Display
Setting/selection
Lat. and sp. lat. tapping start
0 = ------- no latched tapping start (Ex works)
1 = ------- latched tapping start possible
One or two-wire feed operation
0 = ------- single operation (Ex works)
1 = ------- dual operation, this unit is the "master"
2 = ------- dual operation, this unit is the "slave"
Special latched tapping time
0 = tapping function switched off
1 = 300ms (Ex works)
2 = 600ms
JOB list changeover
0 = ------- task-oriented JOB list
1 = ------- actual JOB list (Ex works)
2 = ------- actual JOB list, JOB changeover activated via accessories
Lower limit remote JOB switching
JOB range of the function torches (PM 2U/D, PM RD2)
Lower limit: 129 (ex works)
Upper limit remote JOB switching
JOBarea of the function torch (PM 2U/D, PM RD2)
Upper limit: 169 (ex works)
HOLD function
0 = ------- HOLD values are not displayed
1 = ------- HOLD values are displayed (Ex works)
Block JOB mode
0 = ------- Block JOB mode not enabled (Ex works)
1 = ------- Block JOB mode enabled
Program selection with standard torch trigger
0 = ------- no program selection (Ex works)
1 = ------- program selection possible
Switching the operating mode and welding type using the wire feed control
0 = ------- Switching the operating mode and welding type using the wire feed control and
program 0 (factory setting).
1 = ------- Switching the operating mode and welding type using the wire feed control and
programs 0-15.
Mean value display for superPuls
0 = ------- Function switched off.
1 = ------- Function switched on (ex factory).
Predefined pulse arc welding process in the PA program
0 = ------- Predefined pulse arc welding process in the PA program is disabled.
1 = ------- If the superPuls and welding process switching functions are available and acti-
vated, the pulse arc welding process is always executed in the main program
PA (ex factory).
Predefined absolute value for relative programs
Start program (P
START
), down-slope program (P
B
) and end program (P
END
) can be set re-
lative to the main program (P
A
) or in an absolute manner, as desired.
0 = ------- Relative parameter setting (ex factory)
1 = ------- Absolute parameter setting
Electronic gas flow control, type
1 = ------- type A (ex works)
0 = ------- type B