Functional characteristics
MIG/MAG welding
54
Item No.: 099-005073-EWM01
5.2.11.12
N cycle setting
The n cycle function should always be activated before the n cycle setting (see "Program
changeover with standard torch (P8)".
Operating
element
Action Result
Display
3 sec
Select wire burn-back
1 x
Select N cycle setting
m/min
Parameter setting (setting range 1 to 9)
5.2.11.13
Latched/special-latched tap start (P9)
In latched – tap start – operating mode it is possible to switch straight to the second step by tapping the
torch trigger; it is not necessary for current to be flowing.
The welding can be halted by pressing the torch trigger for a second time.
5.2.11.14
"Single or dual operation" (P10) setting
If the system is fitted with two wire feeds, no further accessory components may be operated on
the 7-pole connection socket (digital)!
This relates to digital remote controls, robot interfaces, documentation interfaces, welding torches with
digital control lead connection, etc.
No second wire feed may be connected in single operation (P10 = 0)!
• Remove connections to the second wire feed
In dual operation (P10 = 1 or 2), both wire feed units must be connected and configured differently
on the controls for this operating mode!
• Configure one wire feed unit as the master (P10 = 1)
• Configure the other wire feed unit as a slave (P10 = 2)
Wire feed units with key switches (optional, see Key switches chapter) must be configured as
masters (P10 = 1).
The wire feed configured as the master is active after the welding machine is switched on. There are no
other functional differences between the wire feeds.
5.2.11.15
Latched special tapping time setting (P11)
The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 300ms (factory setting)
2 = 600ms