Functional characteristics
Advanced functions on the wire feed unit control
90
Item No.: 099-004833-EWM01
5.10
Advanced functions on the wire feed unit control
5.10.1
Special parameter, “M3.70/M3.71”
The special parameters cannot be viewed directly since they are normally only set and stored once. The
machine control offers the following special functions:
5.10.1.1
Special parameters list
Function
Setting options
Ex works
P1
Ramp time for wire inching
0 = normal inching
(10 sec ramp time)
1 = fast inching
(3 sec ramp time)
1
P2
Program “0”, block
0 = P0 enabled
1 = P0 blocked
0
P3
Powercontrol torch display mode 0 = normal display
1 = alternating display
0
P4
Program limit
Program 2 to max. 15
15
P5
Special cycle in the special
latched and non-latched
operating modes
0 = normal (previous) non-latched/latched
1 = DV3 cycle for non-latched/latched
0
P6
Release of special JOBs SP1–
SP3 (effective with M3.70 only)
0 = no activation
1 = activation of SP1–3
0
P7
Correction operation, threshold
value setting
0 = correction operation switched off
1 = correction operation on
The control signals that the correction
operation is on by flashing the LED “main
program (PA)”
0
P8
Program switching with standard
torch
0 = normal (previous) latched, special latched
1 = special latched
2 = specific latched special (N cycle)
(for PROGRESS and EXPERT series only)
0
P9
Lat. or lat. sp. tapping start
0 = normal (previous) latched
1 = latched tapping start possible
0
P10
Single or DUAL WF mode
0 = single WF
1 = DUAL mode (WF unit 1, master)
2 = DUAL mode (WF unit 2, slave)
(for PROGRESS and EXPERT series only)
0
P11
Special latched tapping time
0 = Tapping switched off
1 = 300ms
2 = 600ms
1
Swi
Software key switch
0 = system complete
1 = system not complete
(key switch realised in software for PHOENIX
BASIC models)
1