Design and function
Machine configuration menu
52
099-007033-EW501
4.1.2022
Display
Setting/selection
Alternative welding start – tapping start
Available from torch mode 11 (welding stop by tapping remains active).
------- Function enabled (ex works)
------- Function disabled
Up/down speed
Increase value > rapid current change
Decrease value > slow current change
Current jump
Current jump setting in ampere
Get JOB number
Set maximum selectable jobs (setting: 1 to 128, factory setting 10).
Additional parameter after activating the BLOCK JOB function.
Start JOB
Set first JOB to get (setting: 129 to 256, factory setting 129).
Machine configuration
Settings for machine functions and parameter display
Absolute value setting (ignition, secondary, end and hot start cur-
rent)
> see 4.4.7 chapter
------- Welding current setting, absolute
------- Welding current setting, as a percentage of the main current (ex works)
Non-latched operation (version C)
------- Function enabled
------- Function disabled (ex works)
RINT X12, JOB control for automation solutions
------
on
------
off (factory setting)
Pulsed TIG welding (thermal)
------- Function enabled (ex works)
------- For special applications only
TIG average value pulsing
------- Average value pulsing enabled
------- Average value pulsing disabled (ex works)
TIG average value pulsing
------- Average value pulsing enabled
------- Average value pulsing disabled (ex works)
Pulsed TIG welding (thermic) in the upslope and downslope
phases
> see 5.4.1.3 chapter
------- Function enabled (ex works)
------- Function disabled
TIG antistick
> see 5.3.3 chapter
------- function active (factory setting).
------- function inactive.
Show warnings
> see 7.1 chapter
------- Function disabled (ex works)
------- Function enabled
Setting the system of units
------- Units of length in mm, m/min. (metric system)
------- Unit of length in inches, ipm (imperial system)
Machine configuration (second part)
Settings for machine functions and parameter display