Maintenance, care and disposal
Maintenance schedule
38
099-005630-EW501
02.03.2021
Figure 6-7
• Clean the machine fan with compressed air free of oil and water.
Block the fan wheel of the machine fan mechanically (the machine fan may over-rotate due to the
compressed air and be damaged as a result)!
• Blow out the inverter through both fan openings from the back to the front with compressed air free of
oil and water. Do not blow directly towards external electronic components.
Follow the official regulations for the disposal of dirt residues!
Figure 6-8
• Push the machine fan back in (note the installation direction).
• Reconnect the plugs of the supply lines to the machine fan.