Contetns
eLR100-UL-00 Manual for Consumer Products, Rev. 0.2, 02/2020
20 | 24
Figure 19. PCB Trace
4.3.4
Test Procedure for ensuring compliance
The below test is to be performed both at design verification stage and in production for ensuring compliance.
1. Initiate Continuous Transmission in the appropriate modulation mode from the device i.e.,902.3MHz, 908.7MHz,
914.9MHz; FHSS mode and 903MHz, 907.8MHz, 914.2MHz; DTS mode
2. Verify RF power through conducted measurement at junction J2
3. The measured Tx power should be within the datasheet specification for Transmit output power.