E-80-136KTL User Manual
Copyright ©EVOLVE ENERGY GROUP CO.,LTD
- 58 -
ID06
OVRT
OVRT faulty
ID07
LVRT
LVRT faulty
ID08
IslandFault
Islanding faulty
ID09
GridOVPInstant1
Grid instantaneous
voltage too high 1
ID10
GridOVPInstant2
Grid instantaneous
voltage too high 2
ID11
VGridLineFault
Grid Line voltage
Faulty
ID12
InvOVP
Inverter
overvolatge
ID17
HwADFaultIGrid
The grid current
sampling error
ID17-ID24 are internal faults of
inverter, turn OFF the
“
DC
switch
”
, wait for 5 minutes, then
turn ON the
“
DC switch
”
.
Check whether the fault is
rectified. If no, please contact
technical support.
ID18
HwADFaultDCI
The DCI sampling
error
ID19
HwADFaultVGrid(
DC)
Grid voltage
sampling faulty
(
DC side
)
ID20
HwADFaultVGrid(
AC)
Grid voltage
sampling faulty
(
AC side
)
ID21
GFCIDeviceFault(D
C)
Current leakage
sampling
(
DC
side
)
ID22
GFCIDeviceFault(A
C)
Current leakage
sampling
(
AC