1.2.1.5. Data (RS422) Connection
M12 Connection socket for DATA serial interface, RS422.
In
View → Application parameters → System → Connection settings (C OM)
the serial settings can be
changed.
1.2.1.6. Plug Connections
PIN assignment, connection 24 V DC
PIN
Color
Use
1
BN
+ Ub (24V DC)
2
BU
GND
3
WH
IN (external trigger)
4
GN
OUT 0
5
PK
IN 1
6
YE
IN 2
7
BK
IN 3, LED C
8
GY
OUT 3, LED C
9
RD
OUT (external illumination)
10
VT
IN 0
11
GYPK
OUT 1
12
RDBU
OUT 2 (ejector, max. 100mA), LED A
Table 2
Use only shielded cables.
Connect large area of shield to ground.
PIN assignment, connection LAN
(M12) 4 pin
Color
PIN (RJ45)
Cross-over
1
yellow
3
RxD+
2
white
1
TxD+
3
orange
6
RxD-
4
blue
2
TxD-
Table 3
PIN assignment DATA
PIN
Color
Use
Use
RS422
RS232
1
white
RxD+
NC
2
brown
RxD-
Rx
3
black
TxD+
Tx
4
blue
TxD-
NC
5
grey
GND
GND
Table 4