background image

1.2.1.5. Data (RS422) Connection

M12 Connection socket for DATA serial interface, RS422.

In 

View → Application parameters → System → Connection settings (C OM) 

the serial settings can be 

changed.

1.2.1.6. Plug Connections

PIN assignment, connection 24 V DC

PIN

Color

Use

1

BN

+ Ub (24V DC)

2

BU

GND

3

WH

IN (external trigger)

4

GN

OUT 0

5

PK

IN 1

6

YE

IN 2

7

BK

IN 3, LED C

8

GY

OUT 3, LED C

9

RD

OUT (external illumination)

10

VT

IN 0

11

GYPK

OUT 1

12

RDBU

OUT 2 (ejector, max. 100mA), LED A

Table 2

Use only shielded cables.
Connect large area of shield to ground.

PIN assignment, connection LAN

(M12) 4 pin

Color

PIN (RJ45)

Cross-over

1

yellow

3

RxD+

2

white

1

TxD+

3

orange

6

RxD-

4

blue

2

TxD-

Table 3

PIN assignment DATA

PIN

Color

Use

Use

RS422

RS232

1

white

RxD+

NC

2

brown

RxD-

Rx

3

black

TxD+

Tx

4

blue

TxD-

NC

5

grey

GND

GND

Table 4

Summary of Contents for EyeCheck 9 Series

Page 1: ...EyeCheck 9xx and 1xxx Hardware Manual ...

Page 2: ...Check EyeVBox EVBasic Script EyeView EyeControl EyeScan 3D SmartMatch KeyMatch SolarEye are trademarks of EVT AG registered in Germany and other countries Even though EVT has reviewed this document EVT makes no warranty or representation either express or implied with respect to this document its quality accuracy merchantability or fitness for a particular purpose As a result this document is prov...

Page 3: ...nting hinge MG2A no 543 11023 Observe the object clearance given in the table Field of View Working Distance To avoid interfering reflection from the detection object align the Eyesight Vision System at an angle of approx 10 15 with reference to the optical axis fig 1 Fine adjustment Important Fine adjustment of the Eyesight Vision System should not be carried out until after electrical connection...

Page 4: ...o the system If necessary re set the IP address of the EyeCheck Vision System When the EyeCheck Vision System is in use the protective caps supplied must be pushed onto the M12 sockets data and LAN which are not in use Failure to do this may cause malfunction 1 2 1 Connection Possibilities For stand alone operations independent of PC PLC only connection 24V DC is required after start up For electr...

Page 5: ...lug connection see table 2 1 2 1 4 LAN Connection M12 Connection socket for Ethernet connection For the exact plug connection see table 3 Use only the correct network cables Direct connection of the Eyesight Vision System to a PC recommended Connection of the EyeCheck Vision System to a PC via a network EyeCheck M12 RJ45 PC Ethernet cable CI L4MG RJ45G SG xm PUR EyeCheck M12 Ethernet cable Standar...

Page 6: ...rigger 4 GN OUT 0 5 PK IN 1 6 YE IN 2 7 BK IN 3 LED C 8 GY OUT 3 LED C 9 RD OUT external illumination 10 VT IN 0 11 GYPK OUT 1 12 RDBU OUT 2 ejector max 100mA LED A Table 2 Use only shielded cables Connect large area of shield to ground PIN assignment connection LAN M12 4 pin Color PIN RJ45 Cross over 1 yellow 3 RxD 2 white 1 TxD 3 orange 6 RxD 4 blue 2 TxD Table 3 PIN assignment DATA PIN Color Us...

Page 7: ...r technology EyeCheck 9xx CMOS mono color EyeCheck 1xxx CMOS mono color Integrated scan illumination 8 LEDs except C Mount Integrated lens focal length 6 or 12 mm adjustable focus Sensortype EC9xx EC9xx EC1xxx Lens ajustable to infinity 6 12 12 Min scan distance 6 30 30 Min field of view X x Y 5 x 4 8 x 6 16 x 13 Mechanical Data Length x width x height 65 x 45 x 45 mm without plug Weight approx 16...

Page 8: ...3 Dimensional Drawings EyeCheck 9xx and 1xxx EyeCheck 9xx and 1xxx C Mount Mounting clamp MK 45 supplied with EyeCheck Vision System ...

Reviews: