Page | 4 User manual for evplug charger 7.4 kW PN. EV32002
www.evplugchargers.com
J5
J4 J3
J2
J5
J4 J3
J2
16A
27A
3.7kW
6.2kW
J5
J4 J3
J2
J5
J4 J3
J2
23A
32A
5.3kW
7,4kW
SPECIAL CONFIGURATION:
1. Cancel on RFID card
Make this modification if you want to remove the security of the charger, so that when plugged in it starts
charging without having to activate it through the RFID card.
J5 pin setting, the first counting from the left.
RFID ACTIVE: The jumper is inserted into the
bottom two pins ( middle) and the
RFID card starts / stops charging.
RFID OFF: The jumper is inserted in the two
upper pins (upper + middle) and works plug &
play. You do not need an RFID card.
2. Change from 7.4kW to 6,2 - 5,3 - 3,7 kW of maximum load
Reduce the maximum load power in the event that you cannot install a higher power due to installation
limitations. Being able to reduce the maximum power of the load from 7.4 to 6,2 - 5,3 - 3,7 kW.
Place the jumpers for connectors J3 and J4, in
this case the second and third from the left.
For example 7.4kW (32A), the jumper is
inserted into the bottom two pins (
middle) and the output current is 32A.
For 3.6kW (16A), the jumper of Jumper J4 is
inserted in the two upper pins (upper +
middle) and the output current is 16A.