background image

 
 

10 

Personal safety

 

 

Always use ear and eye protection when working with the machine or perform maintenance.  

 

Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and 
gloves away from the power tool. Loose clothes, jewellery or long hair can become 
entangled in the moving parts. 

Service

 

Your power tool should be serviced by a qualified specialist using only standard spare parts. This 
will ensure that it meets the required safety standards. 

 

Specific safety instructions for air compressor

 

 

WARNING! Make sure that both air consumption and maximum effective 
pressure of pneumatic tools are compatible with the pressure set by the pressure 
switch and the volume of air supplied by the compressor.

 

 

During operation the compressor and pipes reach high temperatures. Contact causes burns. 

 

Keep a minimum distance of 4 meters between the compressor and working are 

 

The compressor gases must not contain substances that could lead to fire  

 

or explosion in the compressor. 

 

During operation, to ensure correct lubrication,the compressor must be placed on a stable 
horizontal surface. 

 

To ensure optimal cooling, the compressor will be placed at a minimum distance of 50 cm 
from the wall. 

 

When uncoupling, the hose will be held by hand to avoid injury from thrown back by 
pressure. 

 

Always wear safety goggles to protect your eyes from flying objects that may be lifted by jet. 

 

Do not weld the tank .In case of faults or corrosion, is necessary to be replaced immediately. 

 

Avoid using air pipes and power extension cables with excessive length. 

 

To extend operating life, the compressor must be used in a suitable environment, 

“( well-

ventilated, and never in places affected by dust, acids, vapors, explosive or flammable gas at 
an ambient tempe 5 ° C ... + 40 ° C. 

 

The machine is double insulated. This means it has two completely independent types of 
insulation that prevents the operator to enter into direct contact with the metal parts. This 
measure represents the highest degree of protection against electrocution. 

 
Application 

This tool is intended for personal use for for the production of compressed air. DO 

NOT RUN THE COMPRESSOR WITH ANY OTHER TYPES OF GAS  
Operations: swelling, operations that require connection of pneumatic tools, painting, washing with 
aqueous detergent, by following the specific rules. 
IT IS NOT DESIGNED FOR PROFFESIONAL USE. 
 

Description 

 
1.Air filter  

 

 

 

9. Transport handle 

2. Pressure tank     

 

 

10.Safety valve 

3. Wheel   

 

 

 

11.Drain valve 

4. Support foot 

 

 

 

12.Pressure gauge for tank 

5.Quick coupling for adjusted pressure   

13.Oil level eyehole 

6. Pressure gauge for adjusted pressure  

14.Oil filling cap 

7. Pressure regulator  

 

 

15.Oil discharge screw 

8. On/Off switch 

 

 

 

16.Quick coupling for pressure tank takeover 

 

 

Summary of Contents for CA2024

Page 1: ...1 MANUAL DE UTILIZARE USER S MANUAL COMPRESOR AIR COMPRESSOR CA2024 www honest ro...

Page 2: ...cate pot crea accidente Nu utilizati unealta in zonele cu potential exploziv de exemplu in prezenta lichidelor gazelor sau particulelor inflamabile Uneltele electrice genereaza scantei care pot aprind...

Page 3: ...mpusa de presostat si cu volumul de aer generat de compresor Pe timpul functionarii compresorul si conductele ating temperaturi inalte Contactul cu acestea provoaca arsuri Pastrati o distanta de minim...

Page 4: ...iile respectarii normelor specifice NU ESTE PROIECTAT PENTRU UZ INDUSTRIAL Parti componente 1 Fitru de aer 2 Rezervor sub presiune 3 Roata 4 Picior suport 5 Cupla rapida presiune reglata 6 Manometru p...

Page 5: ...este reglat pe presiunea maxima admisa a rezervorului de presiune Nu este permisa modificarea ventilului de siguranta sau indepartarea sigiliului Pentru ca ventilul de siguranta sa functioneze corect...

Page 6: ...ocuit dup fiecare 500 de ore de func ionare Pentru a inlocui uleiul opri i motorul i scoate i techerul din priz Dup ce a i evacuat complet aerul din rezervor pute i s de uruba i busonul de evacuare al...

Page 7: ...ntr un loc racoros si uscat evitand temperaturile prea ridicate sau scazute Nu depozitati ma ina de spalat sub presiune n aer liber sau la temperaturi sub limita de inghet Pompa va fi grav deteriorata...

Page 8: ...tul este diminuat compresorul porneste din ce in ce mai des nivelul de presiune este scazut Consumul de aer este excesiv Reduceti necesarul de aer comprimat Cuplajele sau tuburile nu sunt etanse Verif...

Page 9: ...gnite the dust or fumes Keep children and bystanders at a distance when operating a power tool Distractions can cause you to lose control of it Electrical safety Always check that the power supply cor...

Page 10: ...ury from thrown back by pressure Always wear safety goggles to protect your eyes from flying objects that may be lifted by jet Do not weld the tank In case of faults or corrosion is necessary to be re...

Page 11: ...g It can be plugged into any socket with protective contact 230V 50Hz which is equipped with a safety 16 A Before starting check whether the mains voltage corresponds to the operating voltage stated o...

Page 12: ...ts dust and dirt intake It is necessary to clen the filter afterno more than 100 hours of operation A clogged air filter greatly reduces compressor power Remove the filter and loosen the butterfly scr...

Page 13: ...otect it from exposure to direct sunlight Keep it in the dark if possible Don t keep it in plastic bags to avoid humidity build up Warranty This warranty covers all material or production flaws exclud...