MFC
Maintenance
7.
203
7. Maintenance
7.1
Maintenance Schedules
Please note
The following maintenance schedules are recommendations only.
Adhere to the appropriate standards, regulations and locally
applicable guidelines.
Task
Period/ Interval
page
DEPOLOX
®
5 flow block assembly
Check for tightness
daily
Comparative measurement, calibrate if necessary
daily/acc. to guidelines
Check electrolyte level
weekly
Check cell sand
weekly
Clean fine filter if membrane cells are used
every 2 months
(depending on how dirty
it is)
Replace cell sand
Every six months
Replace electrolyte
Every six months
Diaphragms
Every six months
(depending on how dirty
it is)
Membrane sensors FC1, TC1, OZ7, CD7
Comparative measurement, calibrate if necessary
daily
Replace electrolyte
Every six months
Replace membrane cap
annually
pH measurement
Comparative pH measurement, calibrate if
necessary
weekly/
acc. to guidelines