MFC
Maintenance
7.
209
Cleaning/replacing the fine filter
Please note
A fine filter must only be installed when membrane sensors are
employed.
Please note
The fine filter must be cleaned or replaced in order to protect the
membrane sensor's delicate membrane against soiling or
damage.
A Knurled nut
B O-ring
C Fine filter
D Filter unit
1
Release both knurled nuts (A).
2
Remove complete filter unit (D).
3
Remove the fine filter (C).
To do this, screw the M6 screw slightly into the fine filter and
pull the fine filter out of the filter unit
or
Press the fine filter (C) with a suitable tool (not pointed) out of
the filter unit.
4
Rinse the fine filter (C) with water, replace if necessary.
5
Place the fine filter (C) into the filter unit (D).
Ensure that the O-ring is fitted correctly (insert as far as
possible).
6
Fit the filter unit (D). Ensure that it is fitted in the correct
position.
7
Tighten both knurled nuts (A).