TO REMOVE A UV BULB:
It is not necessary to stop the water circulating through the evoUV to change
the bulb.
1.
Disconnect the electricity supply.
2.
Unscrew the black end cap at one end of the unit. Take care not to unscrew the
white locking nut also.
3.
Carefully slide the black end cap over the wire to reveal the bulb socket.
Take care not to lose the end cap sealing ring.
4.
Disconnect the bulb socket.
5.
Repeat steps 2 to 4 at the other end of the evoUV.
6.
With the end caps out of the way, carefully slide out the UV bulb.
WARNING:
If the end caps / electrical connections get wet during this procedure,
please ensure that they are thoroughly dried before re-connecting.
TO INSTALL A NEW UV BULB:
Follow the instructions on
page 12
to fit a new UV bulb.
IMPORTANT:
After checking all the fittings are correctly tightened you can switch
your unit back on.
Dirt or limescale building up on the quartz sleeve will inhibit the penetration of the
ultraviolet light into the water and affect the efficient working of the unit.
UV BULB REPLACEMENT
ALWAYS ISOLATE THE UNIT FROM ANY ELECTRICITY AND WATER SUPPLIES
BEFORE CARRYING OUT MAINTENANCE ON THE UNIT.