Evo Spot 180 User’s Manual Ver. 1.00
Page
23
13
13
0..225
max to min speed
226..235
blackout by movement
236..245
blackout by all wheel changing
246..255
no function
1 4
1 4
Special function
0..19
No function
20..29
No function
30..39
Gobo Change to any position
40..79
No function
80..84
All Motor reset
85..87
Scan motor reset
88..90
Colors motor reset
91..93
Gobo motor reset
94..96
no function
97..99
Other motor reset
100..119
Internal program 1
120..139
Internal program 2
140..159
Internal program 3
160..179
Internal program 4
180..199
Internal program 5
200..219
Internal program 6
220..239
Internal program 7
240..255
Internal Sound program 1
Vector Mode
Value
Function
15
Color Time
0..255
max to min speed
16
Gobo Time
0..255
max to min speed
Maintenance & service
o
Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause
greater accumulation of dirt on the fixture’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days.
o
Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy
troubleshooting:
The fixture does not work, no light
o
Check the connection of power and main fuse.
o
Measure the mains voltage on the main connector.
Not responding to DMX controller
o
DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
o
If the DMX LED is on and no response to the channel, check the address settings and DMX
polarity.
o
If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the