EvoJet 0288 Manual Download Page 15

Jetronic-BOX HV  Instructions 2.1

3/4/5:RC3/4/5-CONTROL – Settings for the Outputs RC3, RC4 and RC5

30:RC3-MODE

Specifies the basic function for the remote control output RC3.

OFF

:

The output is switched off and disabled.

RC1-DIRECT

  for gears and doors that remain open (bistable function)

The remote control signal OFF/ON at the RC1 input switches the output between 
the positions 

IN

 (retracted)=34:RC3-LOW and 

OUT

 (extended)=

36:RC3-HIGH.

RC1-TRIGGER

  for doors that close again automatically (monostable function). An OFF

ON 

change of the remote control signal at the RC1 input switches the output to the 
position 36:RC3-HIGH for the times specified with 31:RC3-WAIT-OUT (RC1=ON).
An ON

OFF change of the remote control signal at the RC1 input switches the 

output to the position 36:RC3-HIGH for the times specified with 32:RC3-WAIT-IN 
(RC1=OFF). After this time, the output returns to the position 34:RC3-LOW.

RC1-TRIGGER-LOOP

  (switchable endlessloop)

   This function toggles the servo at RC3/4/5 automatically, as long as RC1 input is 
   switched. All settings 31 – 38 can be used to adjust.

The value 37:DELAY must always be equal or higher as the time for the end- 
positions 31 and 32.

RC1-DIR.&POS. 

works like RC1-DIRECT, but is logical AND'ed with the retracts position-switch. 

For this 22:RC2-MODE must be set to POS.-SWITCH.

RC1-TRIG.&POS. 

works like RC1-TRIGGER, but is logical AND'ed with the retracts position- 

switch. For this 22:RC2-MODE must be set to POS.-SWITCH.

RC1-PROP

:

The output follows the remote control signal at the RC1 input proportional.

   All settings 31 – 38 can be used to adjust.

15

Summary of Contents for 0288

Page 1: ...Jetronic BOX HV 0288 R C Controller Doorsequencer with Air Failsave 2013 evoJet GmbH Am Parir 4A D 52379 Langerwehe Germany www evojet de...

Page 2: ...sequencer 4 Factory Setting Doorsequencer 5 Jetronic Display EDT Engine Data Terminal 6 JETRONIC BOX Setup 7 1 BOX SETUP Menu 8 2 RC CONTROL Menu 11 3 4 5 RC 3 4 5 CONTROL Menu 14 6 TEST DEVICES Menu...

Page 3: ...BOOSTER EDT no 6813 10 Graupner ONBOARD EDT no 6813 7 These units are equipped with an illuminated alphanumeric display and can be connected and disconnected while the system is running or they can be...

Page 4: ...Jetronic BOX HV Instructions 2 1 Schematic Overview Doorsequencer 4...

Page 5: ...output Single action brake valve 22 RC2 MODE OUT RC1 RC3 output gear valve or servo 30 RC3 MODE RC1 DIRECT 31 RC3 WAIT OUT 1 0 seconds the landing gear waits before extend 32 RC3 WAIT IN 1 0 seconds t...

Page 6: ...HT areas In the BOX SETUP menu under 12 EDT LEFT and 13 EDT RIGHT you can choose either to display one of the R C ports RC1 to RC5 or an air pressure value bar or psi In the lower line of the display...

Page 7: ...g the firmware configuration first press the SET key then use the Up Down keys to switch between the available items To leave the SETUP menu and to return to the BOX status display press the SET key f...

Page 8: ...e SET key then use the Up Down keys to switch between the available items To leave the 1 BOX SETUP menu and to return to the SETUP menu press the SET key for more than 2 seconds ESC Pressing the SET k...

Page 9: ...RC1 Remote control input RC1 range ON OFF NO A marks the signal as FAIL signal controlled by 14 AIR FAIL and 24 AIR FAIL A marks the signal as preset defined configured by 21 RC1 PRESET RC2 Remote co...

Page 10: ...scription Default setting NO Set value to YES and push the SET key two times Landing Gear with different Door Controls RC4 RC5 RC3 The landing gear waits 1 second before retraction extension RC4 The d...

Page 11: ...SET key then use the Up Down keys to switch between the available items To leave the 2 RC2 CONTROL menu and to return to the SETUP menu press the SET key for more than 2 seconds ESC Pressing the SET...

Page 12: ...fault setting OFF 22 RC2 MODE Specifies the function for the remote control terminal RC2 OUT RC1 Outputs the RC1 input 1 1 e g for a brake valve NORMAL Standard remote control input ON 1 65 ms OFF 1 2...

Page 13: ...safe function activates an ON signal OUT at RC1 extend gear On the dis play this is indicated by a at the RC1 or RC2 status OFF No air pressure failsafe function IN RC1 Input RC1 is switched to IN OFF...

Page 14: ...r first press the SET key then use the Up Down keys to switch between the available values A marks the value to be set Pressing the SET key finishes the procedure and saves the new value To leave the...

Page 15: ...of the remote control signal at the RC1 input switches the output to the position 36 RC3 HIGH for the times specified with 32 RC3 WAIT IN RC1 OFF After this time the output returns to the position 34...

Page 16: ...fies the lower end position LOW Range 150 Default setting 100 35 RC3 MID Specifies the middle position MID Range 150 Default setting 0 36 RC3 HIGH Specifies the upper end position HIGH Range 150 Defau...

Page 17: ...st function first press the SET key then use the Up Down keys to test the respective system setting A marks the setting to be applied Press the SET key again to finish a test To leave the 6 TEST DEVIC...

Page 18: ...nge ON high OFF low Default setting value of 21 RC1 PRESET 61 RC2 SIM Simulates an ON OFF signal at the RC2 input as if you would use the switch on the transmitter Range ON high OFF low Default settin...

Page 19: ...Jetronic BOX HV Instructions 2 1 19...

Page 20: ...Jetronic BOX HV Instructions 2 1 20...

Page 21: ...Jetronic BOX HV Instructions 2 1 21...

Page 22: ...V Einkreisventil PRO HV Zweikreisventil Best Nr 0288 0980 0981 0982 8830 8832 conforms with the essential protective requirements as laid down in the directive for harmonising the statutory directives...

Page 23: ...Jetronic BOX HV Instructions 2 1 Notes 23...