P a g e
|
4
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
The appliance shall be installed in accordance with national wiring regulations.
Do not operate your unit in a wet room such as a bathroom or laundry room.
Before obtaining access to terminals, all supply circuits must be disconnected.
An all-pole disconnection device must be incorporated which as at least 3mm clearances in all poles, a
leakage current that may exceed 10mA, residual current device (RCD) having a rated residual operating
current not exceeding 30mA and disconnection must be incorporated in the fixed wiring in accordance with
the wiring rules.
The unit should be installed, operated and stored in a room with a floor area larger than 30m2.
-
The installation of pipe-work shall be kept to a minimum 30 m2
-
Spaces where refrigerant pipes shall be compliance with national gas regulations.
-
Servicing shall be performed only as recommended by the manufacturer.
-
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room
area as specified for operation.
-
All working procedure that affects safety means shall only be carried by competent persons.
Transport of equipment containing flammable refrigerants
-
Compliance with the transport regulations
-
Marking of equipment using signs
-
Compliance with local regulations
-
Disposal of equipment using flammable refrigerants
-
Compliance with national regulations
-
Storage of equipment/appliances
-
The storage of equipment should be in accordance with the manufacturer's instructions. Storage of
packed (unsold) equipment
-
Storage package protection should be constructed such that mechanical damage to the equipment
inside the package will not cause a leak of the refrigerant charge.
-
The maximum number of pieces of equipment permitted to be stored together will be determined
by local regulations.
Summary of Contents for Force i12
Page 1: ...P a g e 1 ...
Page 6: ...P a g e 6 2 Unit Dimensions Force i9 Force i12 unit mm Force i17 unit mm 40 40 40 40 ...
Page 11: ...P a g e 11 4 Usage and Operation Instructions 4 1 Controller Introduction ...
Page 13: ...P a g e 13 4 2 3 Clock Setting 4 2 3 1 Time Setting ...
Page 14: ...P a g e 14 4 2 3 2 Timing Setting ...
Page 15: ...P a g e 15 4 2 4 Silent Silent Timing Setting 4 2 4 1 The Silent Button ...
Page 16: ...P a g e 16 4 2 4 2 Timing Silent Function Setting ...
Page 22: ...P a g e 22 4 4 Interface Drawing 1 Main Board Force i9 ...
Page 23: ...P a g e 23 2 Main board Force i12 Force i17 ...
Page 34: ...P a g e 34 ...