DO NOT DRILL

  

Do not drill any fixings or attachments into the outer casing of the tank. Drilling into the outer casing of the 
tank may damage the heating coil and WILL VOID WARRANTY.

 

 

 

INITIAL STARTUP

 

1.  Press and hold 

 for one second to power on the unit. 

 

2.  To set the time: 

a.  Press 

 

once so the hour digit starts flashing, 

b.  Use 

 

to adjust the hour and press 

 

to confirm, 

c.  Repeat for the minute, day, month and year, 

d.  Press 

 

at any stage to cancel. 

 

3.  Press 

 

until 

 

is displayed. This will activate “Eco Heating” (Heat Pump only) mode and will provide 

the most efficient heating. 

 

4.  During periods of unusually high hot water demand (such as additional occupants staying with you), you can 

activate “High Requirement” mode by pressing 

 

until 

 

is displayed. 

 

5.  In any event where there is a failure within the system, the Electric Element (Hydroboost Mode) can be 

engaged with “one push activation” of the 

 

button until 

 

is displayed. This will provide emergency 

water heating until service can be attended. 

 

6.  For adjustment of timers or activating vacation mode, please refer to our online tutorials at:

 

www.evoheat.com.au/tech-support

 

 

 

 

Summary of Contents for Evo315-C

Page 1: ......

Page 2: ...ller 7 6 2 Operating Functions 8 6 2 1 Startup Shutdown 8 6 2 2 Switching Modes 8 6 2 3 Locking the Controller 8 6 2 4 Setting Checking the Target Temperature 9 6 2 5 Hydroboost Setting 9 6 2 6 Force...

Page 3: ...dvanced energy efficiency technologies and built in smart features to ensure you re provided with clean safe and economical hot water all year round Conforms to AS 3498 2009 Australia and New Zealand...

Page 4: ...year d Press at any stage to cancel 3 Press until is displayed This will activate Eco Heating Heat Pump only mode and will provide the most efficient heating 4 During periods of unusually high hot wa...

Page 5: ...you restart the unit or turn it on manually the unit will not start to run again for approximately 3 minutes This is a protection feature to safeguard the compressor The handle of the P T safety valv...

Page 6: ...eat resistant and durable Piping for the P T Valve The spec of the valve connecting thread is BSP3 4 internal thread After installation confirm that the drainpipe outlet is exposed in the air When the...

Page 7: ...nces to allow airflow to circulate through the unit it is advised to keep a minimum gap between walls fences etc of 1000mm on the air inlet outlet sides 300mm rear clearance 600mm overhead clearance W...

Page 8: ...water temperature and target temperature The electric heater always will be off INTELLIGENT MODE The unit will automatically judge the operation mode according to the ambient temperature HIGH REQUIRE...

Page 9: ...for 0 5 seconds in the running screen of the controller to turn the unit off The main display will now show OFF The unit will dim the screen and display the standby screen when the controller has not...

Page 10: ...5 Hydroboost Setting Also known as the Electric heater the Hydroboost setting allows higher levels of hot water to be produced When there are high hot water usage requirements such as guests staying t...

Page 11: ...ameter value as shown in the below table and press the key to open that value Change the value using the up down arrow keys and press the key to save changes Press to exit the menu Description Paramet...

Page 12: ...t up time A and end time B Press to save the setting and exit back to the main interface Press and hold for 2 seconds the timer display will flash When the timer display flashes choose the start up ti...

Page 13: ...sh when it is selected use the arrow keys to select your desired start day then press to save all changes and exit back to the main interface Note Format is mm dd Example The unit will start up on Sep...

Page 14: ...rs E01 EEV adjustment mode 0 1 1 0 Manual 1 Auto E02 EEV target overheat temp 20 20 5 E03 EEV initial steps 0 500 240 E04 EEV minimum steps 0 500 80 E05 Defrosting EEV steps 0 500 480 System parameter...

Page 15: ...sor shutdown ambient temp 1 30 90 65 R20 The compressor shutdown ambient temp 2 30 90 55 Timing parameters L01 Whether enable the vacation mode 0 1 0 0 Disable 1 Enable L02 The vacation mode Year 0 99...

Page 16: ...p setting needs to be reduced if it is too high 4 Check the high pressure switch If the switch is open when the connection is closed replace it Low pressure protection E02 1 Check if the system is lea...

Page 17: ...BRN BLU Y G 3G2 5mm L N L N N N N N N 1 3 2 4 5 6 7 8 01 N 4 WHT N 4V 1 2 3 4 MTS RESET 1 3 4 2 OUT1 OUT2 OUT3 OUT4 OUT5 AC N 3 4 3 4 CN5 OUT6 CN6 CN1 CN2 12V NET GND 485 A 485 B DI01 DI03 GND DI04 GN...

Page 18: ...80900421 KP cover 640 22 ABS Black Gloss 9005 Plastic Absorption 14 80708081 KP Top Cover Galvanized sheet 0 8 gray white matte 9006 15 80704839 Fan top cover Galvanized sheet 1 0 Black finish 9005 16...

Page 19: ...th the water heater 8 4 Using the Overheating Protector The overheating protector is used to turn the power off in an emergency or with power supply issues preventing the water from being heated too h...

Page 20: ...clean of the unit with a damp cloth MAJOR FIVE YEAR SERVICE It is recommended a major five 5 year service be conducted on the Evo315 C Warning Servicing of a water heater must only be carried out by...

Page 21: ...ed within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 o...

Reviews: