background image

2

2.SPECIFICATION

2.1 Performance data of Swimming Pool Heat  Pump Unit

1. PREFACE

In order to provide our customers with quality, reliability and  versatility, 
been made to strict production standards. This manual  includes all the necessary 
information about  installation, debugging, discharging and maintenance. Please read this 
manual carefully before you open or maintain the unit. The manufacture of this product will 
not be held responsible if someone is injured or the unit is damaged,  as a result of 
improper installation, debugging, or unnecessary maintenance. It is vital that the 
instructions within this  manual are adhered to at all times. The unit must be installed by 
qualified personnel.

this product has 

The unit can only be repaired by qualified installer centre , personnel or an authorised 
dealer.

Maintenance and operation must be carried out according to the recommended time and 
frequency, as stated in this manual.

Use genuine standard spare parts only.
Failure to comply with these recommendations will invalidate the  warranty.

Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature 
constant.   For split type unit, The indoor unit can be Discretely hidden or semi-hidden to 
suit a luxury house.

Our heat pump has  following characteristics:

1 Durable
      The heat exchanger is made of PVC & Copper Nickle  tube which can withstand 
prolonged exposure to swimming pool water.
2 Installation flexibility
      The unit can be installed outdoors or indoors.
3 Quiet operation
      The unit comprises an efficient rotary/ scroll compressor and a low-noise fan motor, 
which guarantees  its quiet operation.
4  Advanced controlling
      The unit includes micro-computer controlling, allowing all operation parameters to be 
set. Operation status can be displayed on the LED wire controller. Remote controller can be 
chosen  as future option.

1

*** REFRIGERANT :  R410A

Model
Heating capacity

Heating Power Input

Running Current

Power Supply
Compressor Quantity
Compressor
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions(L/W/H)
Unit Ship Dimensions(L/W/H)
Net Weight
Shipping Weight 

kW

Btu/h

kW

A

dB(A)

mm

3

m /h

kPa

mm
mm

kg
kg

see nameplate

see package label 

See the drawing of the units

See package lable

Heating: Outdoor air temp:24

/19

, Inlet water temp:26

CS57

57

194500

12.8
20.7

415V/3N

~

/50Hz

2

scroll

vertical

61

60.3
19.5

12            

Summary of Contents for CS57

Page 1: ......

Page 2: ...Heat Pumps Plumbing 3 5 Swimming Pool Heat Pumps Electrical Wiring 3 6 Initial Start up of the Unit 4 Usage and Operation 4 1 4 2 4 3 5 Maintenance and Inspection 5 1 6 Appendix 6 1 6 2 The displayin...

Page 3: ...rding to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty Swimming Pool Heat...

Page 4: ...3 2 2 The dimensions for Swimming Pool Heat Pump Unit 2 SPECIFICATION Models CS57 60 3 60 3 32 1130 1490 1464 480 735 Water inlet Water outlet Drainage Horizontal vision Vertical vision...

Page 5: ...rovided by users or the installer Attention Please follow these steps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with...

Page 6: ...ource of fresh air which reduces it efficiency and may prevent adequate heat delivery 3 2 Swimming Pool Heat Pumps Location Normally the pool heat pump is installed within 7 5 metres of the pool The l...

Page 7: ...r will run down the fins into the basepan and drain out through the barbed plastic condensation drain fitting on the side of the basepan This fitting is designed to accept 3 4 clear vinyl tubing which...

Page 8: ...Time Delay The unit is equipped with a 3 minute built in solid state restart delay included to protect control circuit components and to eliminate restart cycling and contactor chatter This time delay...

Page 9: ...rt the heating mode Function2 pressing this button could turn up and increase the value Function1 continually pressing this button could start the cooling mode Function2 pressing this button could tur...

Page 10: ...he state of power on or power off the measured temperature of B01 B04 could be checked Press or to enter into the temperature interface Press Up or Down to find the needed temperature then press to ch...

Page 11: ...fficiency of the unit Do not make any change of them when it is not necessary r01 r02 r03 r04 are permitted to set by the users For the default values please refer to Parameters Table The permitted se...

Page 12: ...tle water in water system Check the water flow volume water pump is failure or not Low pressure protect Low pressure switch action Check through each pressure switch and return circuit Exhaust tempera...

Page 13: ...eplace filter or capillary 3 clean the water filter and discharge the air in water loop Compressor do not run 1 power supply failure 2 compressor contactor broken 3 power cable loose 4 protection on c...

Page 14: ...e handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 9...

Page 15: ...line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm...

Page 16: ...Note...

Page 17: ...Code 20170514 0002...

Reviews: