6.5 Requirements for the fresh water connection
Each appliance carries the DVGW test symbol and does not require an extra safety
valve in the water feed.
Fresh water connection must be made according to EN 1717 or according to local
regulations.
ATTENTION!
The minimum flow pressure of the clean water supply upstream of the solenoid
valve must be 2,5 bar, if air-gap is incorporated 0,6 bar and if water-softening
equipment (EW 10) is incorporated into the machine: 3bar.
The maximum pressure must not exceed 5 bar
If the flow pressure is below the minimum, increase the flow pressure with a
booster pump; if the maximum pressure is exceeded, limit it with a pressure re-
ducer.
Suitable protective measures must be taken to ensure that no iron particles can
enter the appliance via the mains water supply. Similarly, precautions must be
taken to prevent the entry of other metal particles, for example copper turnings.
Corresponding instructions are contained in the installation drawing. Therefore
suitable measures must be taken.
A dirt trap must be fitted into the fresh water supply to protect the solenoid valve.
Special requirements for Australia
Installation in accordance with AS/NZS 3500
6.6 Requirements for the waste water connection
Build an odour trap into the waste water connection if this is not already built-in
(further information about this is in the Installation drawing / Technical Sheet).
The drain hose must be connected to the waste water pipe in the building.
A grease trap may be needed, depending on the machine application.
6.7 Emergency-off
Switch the machine off completely via the on-site power disconnection device.
6.8 Chemicals for the operation of the appliance
ATTENTION!
Only alkali detergents and acid rinse agents suitable for use in commercial dish-
washers may be used. Corresponding information is submitted by the manufacturers
of such products.
MEIKO recommends brand cleaning products from leading manufacturers. - cleaning
and hygiene products
are an excellent choice.
If unsuitable products are used, the life expectancy of the dosing units can be re-
duced considerably.
Observe the dosing instructions of the manufacturer.
Detergents and rinse-aids can present a health hazard if they are not correctly used.
Please observe the manufacturers’ instructions on the original packing and on the
safety data sheets.
"Items for rinsing are tribologically influenced in particular by chemicals and in-
creased temperatures during the process, as well as mechanical stresses caused by
handling and transporting."
If a de-
scaling agent is used, please strictly observe the manufacturer’s instructions
reg. handling and safety. After having used such an agent, the product must be com-
pletely removed from the machine, as even small residues are sufficient to destroy
plastic parts and packing materials.
Chemical product settings
The correct settings for the quantity of detergent and rinse agent depend on the prod-
uct used. The relevant chemical supplier can install the correct setting.