NPC-8210 

- 19 - 

 

get_sysfan2_speed 

Get system fan 2, and input on CLI interface 

cli>get_sysfan2_speed 

sysfan2_speed=4383rp 

get_sysfan3_speed 

Get system fan 3, and input on CLI interface 

cli>get_sysfan3_speed 

sysfan3_speed=4515rpm 

get_cpufan1_speed 

Get CPU1 fan speed, and input on CLI interface 

get_cpufan1_speed 

cpufan1_speed=2184rpm 

get_cpufan2_speed 

Get CPU2 fan speed, and input on CLI interface 

cli> get_cpufan2_speed 

sysfan2_speed=0rpm 

get_vcore1_value 

Get vcore1 voltage value, and input on CLI interface

cli>get_vcore1_value 

vcore1_value=0.968V 

get_vcore2_value 

Get vcore2 voltage value, and input on CLI interface

cli>get_vcore2_value 

vcore2_value=0.704V 

get_v_3_3_value 

Get actual value of 3.3 voltage, and input on CLI 

interface 

cli > get_v_3_3_value     

v_3_3_value=3.344V 

get_v_5_value 

Get 5V voltage value, and input on CLI interface 

cli> get_v_5_value 

v_5_value=5.041V 

get_v_12_value 

Get 12V voltage value, and input on CLI interface 

cli> get_v_12_value 

v_12_value=12.144V 

get_v_bat_value 

Get vbat voltage value, and input on CLI interface 

cli>get_v_bat_value 

v_bat_value=3.152V 

hwmonitor 

Detect hardware information, and input on CLI 

interface 

cli > hwmonitor 

 

sys_temperature =53

 

cpu1_temperature=57

 

cpu2_temperature=0

 

sysfan1_speed=0rpm 

sysfan2_speed=0rpm 

sysfan3_speed=0rpm 

cpufan1_speed=2033rpm 

cpufan2_speed=0rpm 

Summary of Contents for NPC-8210

Page 1: ...manual can only be handled by qualified and professional personnel During operation please follow the respective instructive manuals especially the safety warnings The professional personnel have bee...

Page 2: ...eval system or transmitted in any form or by any means mechanical electronic photocopied recorded or otherwise without the prior written permission from the manufacturer Trademarks EVOC is a registere...

Page 3: ...thin the manual usually stands for EVOC NPC 8210 Instructions Safety instructions To avoid property losses or individual injury please pay attention to the safety instructions within the manual The wa...

Page 4: ...s before Connection 7 3 2 Product Grounding 7 3 3 Connecting the Device to Power 8 4 Operating Instructions 9 4 1 Outer Appearance 9 4 2 Product External Dimensions and Installation Dimensions 10 4 2...

Page 5: ...allation and Removal of HDD 32 5 5 Installation and Removal of Power Supply 33 5 5 1 Installing the Power Supply 33 5 5 2 Removing the Power Supply 35 5 6 Installation and Removal of Fan 35 5 6 1 Inst...

Page 6: ...power supply and redundant power supply When the chassis is used with NET 2814VD2N B 01 motherboard the chassis provides 3 ENM slots in addition to basic IO ports 1 x standard PCIE x8 slot 2 x 3 5 in...

Page 7: ...l port redirection function externally on front panel COM2 and IPMI function share one channel i e when IPMI function is used COM2 cannot be used COM3 is IPMI external communication port and IPMI code...

Page 8: ...ts basic requirements of GB4943 Mechanical and Environmental adaptability Anti vibration 5 19Hz 1 0mm amplitude 19 200Hz 1 0g acceleration Anti shock 10g acceleration 11ms duration Main Performance In...

Page 9: ...nt power supply 7 When the chassis is used with EF EIO 043NPC 01 IO board the chassis front panel ETH A silk screen printing corresponds to LAN1 of EF EIO 043NPC 01 and IPMI silk screen printing corre...

Page 10: ...ge box when it is not used And warehouse temperature should be 0 C 40 C and relative humidity should be 20 85 In the warehouse there should be no harmful gas inflammable explosive products and corrosi...

Page 11: ...mentation which is a part of the device is required for initial device debugging When doing the initial examination please check whether there are distinct damages to the device caused during the tran...

Page 12: ...the peripheral devices approved for industrial application can be used When operating the device hot swappable IO modules USB can be used The IO devices without hot swap function can only be connected...

Page 13: ...confirm the input voltage is accord with the characteristic of the product supply before insertion NPC 8210 single power supply Steps to connect the device to power Connect the power cable to the red...

Page 14: ...rd Different configuration slight difference in outer appearance In this picture the front panel supports expansion to ENC card NPC 8210 used with NET 2814VD2N B 02 motherboard Different configuration...

Page 15: ...panel may vary slightly based on the mated motherboard and configuration used with NET 2814VD2N B 01 used with NET 2814VD2N B 02 motherboard motherboard Unit mm 4 2 2 Installation Dimensions Drawing N...

Page 16: ...motherboard Unit mm 4 3 External Structure NPC 8210 used with NET 2814VD2N B 01 motherboard Front view of the device Item Description Reset button LED USB CONSOLE port ETH A IPMI port or ETH A ETH B...

Page 17: ...dule BYPASS switch Ground screw VGA Power Power switch NPC 8210 used with NET 2814VD2N B 02 motherboard Front view of the device Item Description Reset button LED USB CONSOLE port ETH A IPMI port or E...

Page 18: ...rovides one 10 100 1000Mbps RJ45 network port LAN1 supporting Wake On LAN Its pin definition is as follows LILED dual color yellow and green Network speed ACTLED single color green Network activity Gr...

Page 19: ...y LILED dual color yellow and green Network speed Flash Data being transmitted Yellow 100Mbps Off No data being transmitted Off 10Mbps 3 The front panel provides two 10 100 1000Mbps RJ45 network ports...

Page 20: ...rection Its pin definition is as follows Pin Signal Name 1 RTS 2 DTR 3 TXD 4 GND 5 GND 6 RXD 7 DSR COM1 8 CTS 4 4 4 Display Port The rear panel provides one VGA port Its pin definition is as follows P...

Page 21: ...trol button Item Description On Off button used to turn on off the device Note To shut off the device you only need to carry out the power off program in the system and you do not have to press this b...

Page 22: ...data communication ACTLED status Green Data communication Off Not linked IPMI LILED status Yellow Being linked NPC 8210 02 Indicator Meaning LED Description Off Disconnected from power PWR Device stat...

Page 23: ...ill be popped out automatically Input or help command to display more information Command Operation method Example result get_sys_temperature Get system temperature and input on CLI interface cli get_...

Page 24: ...get_vcore2_value Get vcore2 voltage value and input on CLI interface cli get_vcore2_value vcore2_value 0 704V get_v_3_3_value Get actual value of 3 3 voltage and input on CLI interface cli get_v_3_3_...

Page 25: ...bove threshold3 the buzzer gives alarm for three times cli set_sys_threshold 60 70 80 cli set_cpu1_threshold 60 70 80 cli set_cpu2_threshold 60 70 80 Set the threshold values according to the actual n...

Page 26: ...92 168 105 3 255 255 255 0 After inputting ip the network is disconnected Use new ip address for login get_log Check abnormal temperature log Input get_log to check abnormal information which includes...

Page 27: ...ng serial port redirection use ESC 7 to replace DEL to enter into system setup program Ctrl S Configure NIC setting for PXE boot if it has been enabled please refer to Using System Setup Program which...

Page 28: ...stalled operating system If you try to boot the operating system from other mode it will cause system bootup failure Note The operating system must be compatible with UEFI e g Microsoft Windows Server...

Page 29: ...Select an option Browse setup in fields by rolling You can key in appropriate value among many fields F1 Display help information of system setup program F2 Restore to system settings before the chang...

Page 30: ...2048 MB DDR3 System Date Thu 12 26 2013 System Time 09 41 55 Access Level Administrator Set the Date Use Tab to switch between Date elements Select Screen Select Item Enter Select Change Opt F1 Genera...

Page 31: ...CPU power management funciton Custom User self defined Energy Efficient Minimum power EIST Enabled Disabled Intel CPU SpeedStep function Turbo Mode Enabled Disabled IntelCPU Turbo Mode function Energ...

Page 32: ...Boot Option filter Set up boot mode Legacy only Boot 32 bit system DOS or 64 bit Legacy system UEFI only Boot 64 bit UEFI system Launch PXE OpROM policy PXE boot mode selection Automatic Power up Mod...

Page 33: ...hronization between host PC and IPMI system IPMI System Time Configuration Enable or disable time synchronization function between hostPC and IPMI system System Security Protection Interface Tabel 13...

Page 34: ...Item Description Item Description Item Description 1 Mounting ear 2 Chassis 3 Rear mount ear 4 Drawable fan module 5 Power supply 6 Wind shield 7 Motherboard 8 Chassis cover 9 Front cover 10 3 5 inch...

Page 35: ...tem Description 1 Mounting ear 2 Chassis body 3 Rear mounting 4 Drawable fan module 5 Power supply 6 Wind shield 7 Motherboard 8 Chassis cover 9 Front cover 10 2 5 inch drawable HDD Optional quantity...

Page 36: ...s cover then pull the cover backward to open the chassis cover 5 3 Installation and Removal of Motherboard 5 3 1 Installing the Motherboard 1 Place the motherboard inside the chassis use ten M3 pan he...

Page 37: ...oosen the ten M3 screws and seven hex studs then you can remove the motherboard 5 4 Installation and Removal of HDD NPC 8210 is used with NET 2814VD2N B 01 motherboard and has two 3 5 inch drawable HD...

Page 38: ...Power Supply When NPC 8210 is equipped with single power supply use six M3 sunkhead screws to fasten the power bracket onto the chassis place the power supply inside the chassis use three sunkhead 6...

Page 39: ...nkhead screws to fasten the power bracket onto the chassis body place the power supply inside the chassis use four sunkhead 6 32 1 4 screws to fasten the power supply onto the bracket then use one M3...

Page 40: ...ews fixing the power bracket power supply and tail end of power supply and pull out the power cable terminal then you can take out the power supply from the chassis 5 6 Installation and Removal of Fan...

Page 41: ...2 Removing the Fan Loosen the two M3 screws on the fan panel then the fan module can be separated from the chassis Lay the fan on the table and reach your fingers into the fan hole to pull out the cab...

Page 42: ...y reinforcement brackets These screws will not fall out from the brackets Directly align the brackets with hex studs and tighten the screws 5 7 2 CF Card Reinforcement Install step screws with gasket...

Page 43: ...se ENC Modular Card The installation stepsare as follows align the converter board gold finger of ENC modular card with PCIE slot of the motherboard insert the card downward with force to the bottom o...

Page 44: ...Installing the Drivers NPC 8210 39 6 Installing the Drivers Regarding the installation of the driver program and the detailed information of the motherboard please refer to the enclosed CD of the PC...

Page 45: ...d The luminance control is set to Black Increase the screen luminance by luminance control Please refer to the instructions of the display for detailed information The external display is black Power...

Page 46: ...isplays Boot device not found In booting priority of the BIOS setting the device is not the first priority or the device is not included in the booting device Modify the booting priority of the device...

Page 47: ...IO card can be used when used again Poor contact of the slot Poor contact is usually caused by frequent installation uninstallation of the PCI or ISA card unstable fixing or improper dust proof measur...

Reviews: