www.evofitness.net.au
17
connected well, please check each wire.
3
.
”E02”
:
You may not have enough voltage going to the machine. Turn the machine off and on
again at the switch at the rear of the treadmill. If this does not fix the problem you may have
damaged the lower circuit board. Contact our service centre on 1300 796 636
4
、
“E03’: No sensor signal. Sensor wire is faulty, replace the sensor wire. Magnetic sensor wire is
not working change the magnetic wire or reset the magnet.
5
、
“E04”: Incline motor wrong, check if the VR of the incline motor connects well or replug it. The
mark of the DC motor and control board should be matched connected. Sometimes you also
need to check the wires of the motor and restart the whole treadmill again.
6
、
“E05”: Current overload protecting. Power surge or the motor is seized which will cause
excessive current. At this time the treadmill will start its self-protecting system. Adjust the
machine and restart; Check if the motor is noisy or if the motor / bottom control board is burnt
out, if burnt out, change the motor and/or bottom control.
7
、
If the motor does not work after pressing the START button, the probable reason: the motor wire
is broken; the safety pipe is broken or disconnected; the motor wire is not connected well; the
IGBT on bottom control board is burnt out. Test the above reasons and change the relevant part.
If this does not fix the problem call our service number 1300 796 636.