13
S
TARTING
, S
TOPPING
, S
HIFTING
Move the remote control handle to NEU-
TRAL.
1. Concealed side mount control
2. Binnacle mount control
Turn the key switch fully clockwise to the
START position. Crank the engine no longer
than 20 seconds.
IMPORTANT:
The starter motor can be dam-
aged if operated
continuously
for more than
20 seconds.
Upon start-up, release the key.
If the engine did not start, release the key mo-
mentarily, then try again.
Each time the key switch is turned from OFF
to ON, the warning system will self-test. Refer
to
warning system fails to self-test during start-
up, see your Dealer.
If your outboard does not react normally to
this starting procedure or if it fails to start, re-
fer to
After Engine Starts
Check the water pump indicator. A steady
stream of water indicates the water pump is
working. If a steady stream of water from the
water pump indicator is not visible, stop the
engine. Refer to
ENGINE STOPPING
Move control handle to NEUTRAL.
Turn key switch counterclockwise to the OFF
position. Remove the key when the boat will
be unattended.
WARNING
If you are using a remote control that
does not have start-in-gear prevention,
the outboard can be started while it is
in gear. Protect against unexpected
boat movement by always starting your
outboard in NEUTRAL.
DO NOT
advance the throttle before start-up.
Advancing the throttle overrides the electron-
ic idle control system. After the engine starts,
the engine management module (
EMM) au-
tomatically increases idle speed slightly. Idle
speed will decrease as the engine warms up.
The
System Check gauge lights will illumi-
nate if the throttle is advanced.
1
2
Summary of Contents for 2004 75 E-TEC
Page 10: ......
Page 11: ...9 USING YOUR EVINRUDE E TEC OUTBOARD USING YOUR E TEC OUTBOARD...
Page 33: ...31 MAINTENANCE...
Page 40: ...38 Maintenance OWNER S NOTES...
Page 41: ...39 PRODUCT INFORMATION...
Page 54: ...52 Product Information...
Page 56: ...54 Product Information...
Page 57: ...55 OWNER S NOTES...
Page 60: ......