E2618-PID
Rev 09.03.2021
0x00FF
255 /
40256
RW
Sensor, analog outputs,
LED and buzzer status
bit[0]=0/1 – sensor
present/absent, RO
bit[1]=0/1 – analog outputs
deactivated/activated
bit[2]=0/1 – in case the sensor
is absent, turn signaling off/on
analog output1
bit[3]=0/1 – in case the sensor
is absent, turn on signaling with
low current/high current on
analog output1; if bit[2]=0 this
bit will be ignored
bit[4]=0/1 – in case of sensor
absent, turn signaling off/on
analog output2
bit[5]=0/1 – in case of sensor
absent, turn on signaling with
low current/high current on
analog output2; if bit[4]==0 this
bit will be ignored
bit[6]=0/1 – current/voltage
output detected on output1, RO
bit[7]=0/1 – current/voltage
output detected on output2, RO
bit[8]=0/1 – LED
deactivated/activated
bit[9]=0/1 – buzzer
deactivated/activated (always
0 for E2618)
bit[10]=0/1 - LED is on/off in
normal condition
Address Reg / MHR RW Description
Supported values (dec)
Default
0x0101
257 /
40258
R
Raw gas sensor data
0...4095, ADC units
0x0103
259 /
40260
R
Gas concentration,
gas units
0...65535, gas units
0x0105
261 /
40262
RW
0% value
for analog output 1
-32000...+32000
(gas unit/°C)
User
defined
0x0106
262 /
40263
RW
100% value
for analog output 1
-32000...+32000
(gas unit/°C)
User
defined
0x0107
263 /
40264
RW
0% value
for analog output 2
-32000...+32000
(gas unit/°C)
User
defined
0x0108
264 /
40265 RW
100% value
for analog output 2
-32000...+32000
(gas unit/°C)
User
defined
34