background image

b

b

b

CloudCell 4G

b

b

Installation manual

b

b

b

 
 

 

b

Summary of Contents for CloudCell 4G

Page 1: ...b b b CloudCell 4Gb b Installation manualb b b b...

Page 2: ...y Paula Araujo IT Project and Process Managerb Alexey Shorokhovb Industrial Designerb Reviewed by Tim Kipleyb Infrastructure directorb Vitaly Klebanb CTOb Slava Vitykb Hardware engineerb b b b b every...

Page 3: ...g 10b 4 10 Recommended equipment 11b Preparing the Gateway and cabling the network part 5 13b 5 1 Connectors specification 13b 5 2 Grounding 14b 5 3 Mount Antenna 14b 5 4 Mount Gateway 16b 5 5 Connect...

Page 4: ...e use of the ground wire as a part of the safety certification b Modification or misuse may provide a shock hazard that could result in serious injury or death b Contact a qualified electrician or the...

Page 5: ...etic or electricalb stress including lightning strikes or accident b Has been damaged as a result of using third party firmware b Has no original EVERYNET label or is missing any other original EVERYN...

Page 6: ...YS CANCELLATIONS DELIVERYb FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGEb RESULTING FROM ANY OF THE FOREGOING In addition EVERYNET does not warrant that theb operation of the Produ...

Page 7: ...ANb b b 4 2 Outdoor Omnidirectional Antenna LoRa antenna must meet these minimumb specificationsb b 50 Ohm N female connectorb 868 MHz or 915 MHz frequency range b Please select frequency range depend...

Page 8: ...on antenna sideb N female on equipment sideb 0 4dB max insertion lossb DC 2GHz operation rangeb 90V breakdown voltageb 30W max input powerb 40 to 85 C temperature rangeb b 4 5 Two Micro SIM cards Plea...

Page 9: ...ding straps requiredb b b 4 7 Butyl mastic tape 3M Butyl Mastic Tape 2212 3M IDb 7000133439b b b 4 8 Clamps and cable ties Antenna mounting clampsb Use only manufacturer approved mountingb brackets to...

Page 10: ...atedb 50 pound testb b 4 9 Ethernet cabling Ubiquiti TOUGHcable PRO Carrierb Outdoor use CAT5eb UV protectedb 24 AWGb Braided shieldb Foil Shieldb Ground wireb b Grounded ethernet connector PoE side b...

Page 11: ...3 pin grounded power cord for PoEb powerb b NOTE Verify with continuity meter that earthb grounding pin of PoE power cable isb continuous thru the power cord b b b 4 10 Recommended equipment Wire str...

Page 12: ...Cat5 cable testerb b b b everynet com 12...

Page 13: ...Preparing the Gateway and cabling the network part 5 5 1 Connectors specification 1 LoRa radio cableb 2 SIM cards holders USB resetb 3 Ethernet cableb b everynet com 13...

Page 14: ...nt for protection against lightning strikes and dissipation of static electricity in the cables and equipment Please see drawing below for grounding diagram b 5 3 Mount Antenna Install the clamps that...

Page 15: ...ng strap to towerb grounding pointb Connect lightning arrestor to antennab Hand tighten RF cable into the antennab NOTE Do not use a wrench or pliers as thisb will damage the gateway or connector b Ti...

Page 16: ...ling tape b Two zip tie wraps shall be used for top andb bottom of sealing area one at top and one atb bottom of connector b b b b Verify weatherproofing on all cableb connectionsb b 5 4 Mount Gateway...

Page 17: ...b b Mount gateway on the tower pole Tightenb steel ring clampsbb b everynet com 17...

Page 18: ...nectb opposite end to the grounding point of theb tower b b Penetrox or anti oxidation agent must beb used when attaching grounding strap tob tower grounding pointb IMPORTANT It is not permitted to gr...

Page 19: ...the gateway and connector b Tightening of RF connectors must be made byb handb b b b Completely wrap all RF cable connectionsb and N connectors with 3M Mastic Tape thenb at least two layers of Super 3...

Page 20: ...eway Use only plastic ties b b b 5 6 Ethernet to gateway cable connection Insert the CONEC housing over the ethernetb cableb b Etch 4 cm of PVC cover with the wireb stripper Carefully remove the braid...

Page 21: ...Orangeb b White Greenb b Blueb b White Blueb b Greenb b White Brownb b Brownb b b Place the wires in the correct order leaveb half the foil to connect the shield to the plug b Insert the wires carefu...

Page 22: ...Insert connector into the CONEC housingb and screw nut b b everynet com 22...

Page 23: ...b Fix the network cable in the tower with cableb ties model 35 56cm every 2 metersb b b b 5 7 Ethernet to PoE adapter cable connection Use TC GND for PoE injector side ofb ethernet cableb b Etch 4 cm...

Page 24: ...b Orangeb b White Greenb b Blueb b White Blueb b Greenb b White Brownb b Brownb b b Place the wires in the correct order b leave half the foil to connect theb shield to the plug b Insert the wires ca...

Page 25: ...h cable mapb tool and continuity testerb b Connect network cable POE port ofb PoE Ubiquiti PoE 48v 24w injectorb b Connect ethernet round wire to theb tower according to the scheme b Connect PoE power...

Page 26: ...et b Ethernet cable shield MUST also beb grounded through the AC ground pin ofb the PoE power cable b 5 8 Verify all the connectors are correct b 5 9 Check LEDs indication Check that the connecting li...

Page 27: ...5 10 Verify gateway is affixed securely on the tower b everynet com 27...

Page 28: ...and can radiate radio frequency energyb and if not installed and used in accordance with the instructions b may cause harmful interference to radio communications bb However there is no guarantee that...

Reviews: