![Everynet CloudCell 4G Installation Manual Download Page 26](http://html1.mh-extra.com/html/everynet/cloudcell-4g/cloudcell-4g_installation-manual_2445390026.webp)
b
b
PoE injector MUST have a detachable 3
b
pin power cord which contains an
b
integral safety ground wire. This
b
ground pin must be
connected to a
b
grounded safety outlet.
b
Ethernet cable shield MUST also be
b
grounded through the AC ground pin of
b
the PoE power cable.
b
5.8 Verify all the connectors are correct
ɉ
b
5.9 Check LEDs indication
ɉ
●
Check that the
connecting
lights are in the
correct colors.
b
LTE – green
b
b
ETH – red or green
b
b
PWR – green or blue
(blue means that the battery is charging)
b
GPS – green
b
LORA – green
b
everynet.com