background image

 

   

 

3

1-YEAR LIMITED WARRANTY 

(U.S. and Canada Only) 

 

EVERWIN  products  are  designed  and  manufactured  to  the  highest  standards  of  both  material  and  workmanship. 
EVERWIN  warrants  to  the  original  retail  purchaser  that  the  product  purchased  is  free  from  defect  in  material  and 
workmanship and agrees to repair or replace at EVERWIN ‘s option any defective EVERWIN pneumatic stapler or nailer 
for a period of one year, subject to the exclusions and limitations described hereunder. To honor a warranty claim, 
EVERWIN and its authorized distributor need proof of purchase, may request the damaged tool, serial number of the 
damaged tool, photos/videos of the defect for test and evaluation to determine whether the damaged tool is within 
warranty conditions; your cooperation in this regard will be appreciated to expedite the claim process and to help with 
EVERWIN’s continuous efforts in quality improvement. 

 

THIS  WARRANTY  IS  IN  LIEU  OF  ALL  OTHER  WARRANTIES,  EXPRESS  OR  IMPLIED,  INCLUDING  BUT  NOT 
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 
EVERWIN SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. 

 

WARRANTY EXCLUSIONS 

 

The following warranty exclusions apply: 

a.  Normal wear parts are not covered by this warranty. Examples of such parts include, o-rings and seals, driver 

blades, bumpers, pistons and piston rings. 

b.  Failure due to normal wear, neglect, abuse, misuse, misapplication, accidents, over-pressure usage, improper 

storage, shipping damages, improper maintenance, operation not within the operation manual’s specification 
etc. are not covered by this warranty. 

c.  Labor charges, loss, repairs from improper maintenance and/or usage of non-EVERWIN parts are not covered 

by this warranty. 

d.  This warranty does not apply to production or industrial tools as defined by EVERWIN; industrial or production 

tools are covered on the following grounds. 

 

GROUNDS FOR INDUSTRIAL / PRODUCTION TOOL COVERAGE 

 

For high production industrial tools, coverage is limited to 90 days due to high volume usage; warranty on production 
tools cannot be guaranteed due to unpredictable circumstances. Tools are subjected to abuse such as hammering or 
usage of adjustment tools, especially true in loan tool programs. Upon receiving a report, EVERWIN and its authorized 
distributor  may  request  the  damaged  tool,  serial  number  of  the  damaged  tool  (as  a  gauge  for  the  tool’s  age)  and 
photos/videos of the defect for test and evaluation to find root causes. EVERWIN’s analyst will judge the issuance of 
defective parts and will replace at no charge if evaluation results show that the root cause is defect in material and/or 
workmanship. 

 

Note: all warranty services will be carried out by EVERWIN authorized repair centers,   

please contact [email protected] for the location most convenient for you. 

 

 

   

 

2

INTRODUCTION 

 

The  tool  is  designed  for  high  speed,  high  volume  nailing.  These  tools  will  deliver  efficient, 
dependable  service  when  used  correctly  and  with  care.  As  with  any  fine  power  tool,  the 
manufacturer’s  instructions  must  be  followed  for  best  performance.  Please  study  this  manual 
before operating the tool and understand the safety warnings and cautions. The instructions on 
installation, operation and maintenance should be read carefully, and the manuals kept for reference. 
NOTE: Additional safety measures may be required because of your particular application of the 
tool. Contact your EVERWIN representative or distributor with any questions concerning the tool 
and its use. Everwin Pneumatic Corp., Taichung City, Taiwan 41353.   

 

INDEX 

 

1-Year Limited Warranty ----------------------------------------------------------------------------------------------  

CE Declaration of Conformity ---------------------------------------------------------------------------------------  

Safety Instructions ------------------------------------------------------------------------------------------------------  

Specifications and Technical Data ------------------------------------------------------------------------------------  

Operating Pressure, Setting Correct Pressure -------------------------------------------------------------------  

Operation ----------------------------------------------------------------------------------------------------------------------  

Air Supply and Connections: Fittings, Hoses, Filters,   

Air Consumption, Regulators, Supply source -------------------------------------------------------------  

Lubrication ---------------------------------------------------------------------------------------------------------------------  

Nail Loading ------------------------------------------------------------------------------------------------------------------   

Tool Operation ---------------------------------------------------------------------------------------------------------------  

10 

Tool Operation Check -----------------------------------------------------------------------------------------------------  

13 

Maintaining the Pneumatic Tool ----------------------------------------------------------------------------------------  

14 

Driver Maintenance Instructions -----------------------------------------------------------------------------------  

14 

Trouble Shooting / Repairs-------------------------------------------------------------------------------------------  

14 

 
 
 
 
 
 
 
 
 

 

Summary of Contents for FCN90

Page 1: ...NCE MANUAL CE DECLARATION OF CONFORMITY 20 8 5 Everwin Pneumatic Corp BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRU...

Page 2: ...itional safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin...

Page 3: ...eals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenanc...

Page 4: ...UMATIC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserkl ring CE Deklara...

Page 5: ...ed the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress con...

Page 6: ...This tool uses a 3 8 18 N P T or 3 8 19 P T male plug The inside diameter should be 280 7 mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air suppl...

Page 7: ...rip mechanism while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assemb...

Page 8: ...r pressure from the tool when disconnected from the supply source HOSES Air hoses should have a minimum of 150 PSI 10 6 kg cm2 working pressure rating or 150 percent of the maximum pressure that could...

Page 9: ...d or user must ensure that proper eye protection is worn Eye protection equipment must conform to the requirements of the ANSI Z87 1 and 89 686 EEC and provide both frontal and side protection NOTE No...

Page 10: ...hers in the work area when connecting to air supply loading operating or servicing this tool Eye protection is required to guard against flying fasteners and debris which could cause severe eye injury...

Page 11: ...CONTINUOUS BUMP FIRE OPERATION WITH SMART TRIGGER The common operating procedure on Contact Trip tools is for the operator to contact the work to actuate the trip mechanism while keeping the trigger...

Page 12: ...anism Push and rotate the Trigger Lock Dial to the trigger free position before driving nails DIRECTIONAL EXHAUST COVER FCN90LB PN90 ALWAYS disconnect air supply before rotating the exhaust cover by h...

Page 13: ...the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION Use the this pneumat...

Page 14: ...e the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that would prevent full volume flow of air to the tool DRIV...