X1200 Series Router Manual
INSTALLATION
Revision 1.3.2
Page 2-11
When connecting two X1200 series routers together in a master/slave relationship make sure that the
REMOTE CTL
port is configured the same at both ends (including the RS232 or RS422 wiring). Use the
cable shown in Table 2-5 for RS-232 wiring and the cable shown in Table 2-6 for RS-422 wiring. For other
applications consult the manual for the equipment your are connecting, configure the port accordingly and
use the information in Table 2-1 and Table 2-2 to make an appropriate cable.
Master 1202 End
Slave 1202 End
9 pin D
Male
Pin
Belden
9729
9 pin D
Male
Pin
1
1
TxD
2
-------2b------
RxD
3
RxD
3
-------1a------
TxD
2
4
4
Gnd
5
---drain 2----
Gnd
5
6
6
RTS
7
-------1b-----
CTS
8
CTS
8
-------2a------
RTS
7
9
9
Frame Gnd
Shield
---drain 1----
Frame Gnd
Shield
Table 2-5: Master 1202 to Slave 1202 Cable – RS-232 Configuration
Master 1202 End
Slave 1202 End
9 pin D
Male
Pin
Belden
9729
9 pin D
Male
Pin
Gnd
1
---drain 2----
Gnd
1
Tx-/TxD
2
-------2b------
Rx-/RxD
8
Rx+/RxD
3
-------1a------
Tx+/TxD
7
RxGnd
4
RxGnd
4
5
5
TxGnd
6
TxGnd
6
Tx+/RTS
7
-------1b-----
Rx+/CTS
3
Rx-/CTS
8
-------2a------
Tx-/RTS
2
9
9
Frame Gnd
Shield
---drain 1----
Frame Gnd
Shield
Table 2-6: Master 1202 to Slave 1202 Cable – RS-422 Configuration
Summary of Contents for X1201-AES4
Page 4: ...X1200 Series Router Manual Revision 1 3 2 This page left intentionally blank ...
Page 10: ...X1200 Series Router Manual vi Revision 1 3 2 CONTENTS This page left intentionally blank ...
Page 12: ...X1200 Series Router Manual Revision 1 3 2 OVERVIEW This page left intentionally blank ...
Page 78: ...X1200 Series Router Manual Revision 1 3 2 SERIAL CONTROL This page left intentionally blank ...