EQX–IP18-IPG
EQX Input and IP Gateway Module
Revision 1.0
Page - 39
7.13. AUDIO NOTIFY
This section will display the health of Input and output Audio signal,
Figure 7-26: Web Interface - Audio Notify Tab
7.13.1. Audio Monitoring Control
Audio Over Level (-45 to 0 dBFS)
•
The control sets the threshold limit for the
Audio Over Level
(relative loudness) before a fault
condition is triggered..
Audio Over Duration (1 to 255 samples)
•
This control sets the duration for the audio over level before a fault condition is triggered.
Audio Silence Level (-80 to -40 dBFS)
•
This control sets the threshold limit for the audio silence level before a fault condition is
triggered.
Audio Silence Duration (1 to 128 seconds)
•
This control sets the duration for the audio silence level before a fault condition is triggered.
7.13.2. Audio Input Notify
Input Audio Traps (Audio Pair)
•
When set True; a fault condition on a
Audio Pair
will send out a trap message to the trap
addresses configured in the Trap Control section of the System tab.
Input Audio Faults
•
This field will display green when there is no fault on the audio and red for a fault indication.
7.13.3. Audio Output Notify
Audio Traps (Outputaudio Pair)