7890MG Series
Universal Media over IP Gateway for 10 x ASI/SD/HD/3G/GE
Page - 40
Revision 0.2
WEBEASY
®
Video Output Hitless Not Ready:
Triggers when hitless switching is not currently available on the
selected port. Not having both Trunks plugged in for example could cause this fault.
Trunk A Stream Loss:
Triggers when the IP stream for this port is lost on Trunk A.
Trunk B Stream Loss:
Triggers when the IP stream for this port is lost on Trunk B.
Trunk A Rx Stream IP Change:
Triggers when a change is made to the IP stream settings for this
port on Trunk A
Trunk B Rx Stream IP Change:
Triggers when a change is made to the IP stream settings for Trunk
B
Port Select:
Brings up the SFP Fault SNMP Error Traps for each SFP/SFP+ Port. The check boxes
on the left will enable or disable these faults from being sent to the SNMP Fault Trap log.
Traps
SFP Type Incorrect:
there can be a maximum of two simultaneous input streams to be sent to the
output Port being selected. These input streams can appear on Trunk A and Trunk B
simultaneously. Typically these will be main and backup input streams.
SFP Rx Power Low:
SFP Optical Receive Power is Low. Threshold is adjusted in the SFP Monitor
TAB
SFP Ethernet Link Status:
SFP Ethernet Link Status Up or Down
SFP Present:
SFP Presence Detect
Trunk Select:
Brings up the Trunk Fault SNMP Error Traps for Trunk A and Trunk B. The check
boxes on the left will enable or disable these faults from being sent to the SNMP Fault Trap log.
Traps
Trunk Error:
Triggers whenever errored seconds appear on the selected Trunk Interface.
Trunk Severe Error:
Triggers whenever severe errored seconds appear on the selected Trunk
Interface.
Trunk Link Down:
Triggers when the trunk link is not active.
Trunk Bandwidth Higher:
Trunk bandwidth is greater than max bandwidth threshold set in Trunk
Port TAB -> Bandwidth High Threshold.
Trunk Bandwidth Lower:
Trunk bandwidth is less than min bandwidth threshold set in Trunk Port