background image

 

  
 
 

 
 
 
 
 
 
 
 

570J2K-HW-X19 

Multi Channel J2K Encoder-Decoder 

 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

© Copyright 2017 
 

EVERTZ MICROSYSTEMS LTD. 

5288 John Lucas Drive 
Burlington, Ontario 
Canada L7L 5Z9 
 
Phone: 

+1 905-335-3700 

Sales: 

[email protected] 

Fax: +1 905-335-3573 

Tech Support:  [email protected]  

Fax: +1 905-335-7571 

Web Page: 

http://www.evertz.com

 

 
Version 1.0, February 2017 
 

The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of 
purchasers of the 570J2K product.  Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 
570J2K product.  Due to on going research and development, features and specifications in this manual are subject to change without notice. 
 
All rights reserved.  No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd.  Copies of 

this manual can be ordered from your Evertz dealer or from Evertz Microsystems

.

 

 

Summary of Contents for 570J2K-HW-X19

Page 1: ...on that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 570J2K product Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 570J2K product Due to on going research and development features and specifications in this manual are subject to change without notice All rights reserved No part of this...

Page 2: ...This page left intentionally blank ...

Page 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Page 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Page 5: ...C 7 3 7 ELECTRICAL 7 3 8 PHYSICAL 7 3 9 ENCLOSURES 8 3 10 ORDERING INFORMATION 8 4 570J2K HW X19 APPLICATION BASED FIRMWARE 9 5 570J2K HW X19 APP A ENCODER WEB INTERFACE 11 5 1 SYSTEM 13 5 1 1 System 13 5 1 2 Control Port Configuration 13 5 1 3 Data Port Configuration 13 5 1 4 Data Port Monitor 14 5 1 5 Temperature Monitor 15 5 1 6 Card Control 15 5 2 PRODUCT FEATURES 16 5 2 1 License Control 16 5...

Page 6: ... 25 5 9 INPUT NOTIFY 26 5 9 1 Encoder Input Notification 26 6 570J2K HW X19 APP B DECODER WEB INTERFACE 27 6 1 SYSTEM 29 6 1 1 System 29 6 1 2 Control Port Configuration 29 6 1 3 Data Port Configuration 29 6 1 4 Data Port Monitor 30 6 1 5 Temperature Monitor 31 6 1 6 Card Control 31 6 2 PRODUCT FEATURES 32 6 2 1 License Control 32 6 2 2 Product Features Supported 32 6 3 SDI INPUT CONTROL 33 6 3 1 ...

Page 7: ...Control 40 6 7 4 MPPM Control 42 6 8 IP INPUT MONITOR 43 6 8 1 Input Stream 44 6 8 2 Input Stream Internal Decoder Core 44 6 8 3 Input IP Packet Monitor 44 6 9 DECODER PROGRAM MONITOR 45 6 9 1 Rx Program Monitor 45 6 9 2 Program Video Monitor 45 6 10 SYSTEM NOTIFY 46 6 10 1 System Monitoring Control 46 6 10 2 System Notify 46 6 11 DECODER NOTIFY 47 7 UPGRADE PROCEDURES 49 7 1 FIRMWARE UPGRADE 49 ...

Page 8: ...EASY System Notify Tab 25 Figure 5 16 WebEASY Input Notify tab 26 Figure 6 1 WebEASY Login Menu 27 Figure 6 2 570J2K HW X19 Main Menu 28 Figure 6 3 WebEASY System Tab Part 1 29 Figure 6 4 WebEASY System Tab Part 2 30 Figure 6 5 WebEASY System Tab Part 3 31 Figure 6 6 WebEASY Product Features Tab 32 Figure 6 7 WebEASY SDI Input Control Tab 33 Figure 6 8 WebEASY SDI Output Control Tab 34 Figure 6 9 ...

Page 9: ...nly warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically undertaken...

Page 10: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page vi Revision 1 0 This page left intentionally blank ...

Page 11: ...will provide auto timing time stamped Ethernet outputs multi resolution JPEG2000 streaming outputs and incorporates patent pending multi path multi flow packet merge base network bit error resilience for 100 QoS The 570J2K HW X19 can be managed via integrated HTTP web interfaces as well as SNMP management via Frame Controller Features Benefits Up to 12x3G HD SD or 3xUHD JPEG2000 Encodes Up to 9x3G...

Page 12: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page 2 Revision 1 0 Figure 1 1 570J2K HW X19 Block Diagram ...

Page 13: ...evision 1 0 Page 3 2 GETTING STARTED The 570J2K HW X19 modules come with a companion rear plate and occupy two slots in 570FR Refer to Figure 2 1 for 570J2K HW X19 Rear and Front plate layout Figure 2 1 570J2K HW X19 Rear Plate and Front Plate Layout ...

Page 14: ...HANDLING OF OPTICAL FIBER The transmission characteristics of the fiber are dependent on the shape of the optical core and therefore care must be taken to prevent fiber damage due to heavy objects or abrupt fiber bending Evertz recommends that the user maintains a minimum bending radius of 5 cm to avoid fiber bending loss that will decrease the maximum attainable distance of the fiber cable The Ev...

Page 15: ...the bottom and the top of the chassis Push the card firmly into the slot ensuring that when it mates with the rear card it has been firmly pushed into a seated position Do not connect any cables to the rear card failure to do this could cause unwanted network issues until the initial configuration has been completed This procedure can be completed to all the other modules and is hot swappable allo...

Page 16: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page 6 Revision 1 0 This page left intentionally blank ...

Page 17: ... interfaces Connector 4 x SFP10G TR13 A 3 4 SERIAL VIDEO OUTPUT Number of Outputs 9 SDI Rise and Fall Time Per SMPTE spec 3 5 IP OUTPUT Ethernet Interface 4 x 1GE 10GE SFP SFP SMPTE 2022 6 Encapsulation MPEG2 TS over IP Ethernet IP Signalling Multicast IGMP V2 V3 SSM Support 3 6 EMBEDDING OF HANC VANC 4x Groups Audio Pass through per encoder All type of VANC data pass through 3 7 ELECTRICAL Power ...

Page 18: ...ced logic capacity 570FR hardware module acting as a bulk J2K encoder decoder encoder licenses sold separately 12 J2K Encodes 9 J2K Decodes and up to 4x10GE interfaces using SFP cages SFPs sold separately Ordering Options SFP Modules SFP10G TR13 A 10GE optical SFP Licensing Options 570IPG X19 CK J2KP60 3G HD SD JPEG 2000 Encoder or Decoder license for 570IPG HW X19 ...

Page 19: ...ilds App A is the encoder application that will allow the 570J2K HW X19 to function as an encoder supporting up to 12 J2K encodes App B is the decoder application that will allow the 570J2K HW X19 to function as a decoder supporting up to 9 J2K decodes The manual will first focus on App A related controls and configurations It will then proceed with APP B related controls and configurations ...

Page 20: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page 10 Revision 1 0 This page left intentionally blank ...

Page 21: ...alled and configured with the required network addresses it can be completely configured using the web interface For doing this simply type the IP address of the control port of the 570J2K HW X19 module in the web browser Note Computer must be on the same Subnet in order to have communication with the module Figure 5 1 WebEASY Login Menu Login and password is root and evertz respectively On the we...

Page 22: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page 12 Revision 1 0 Figure 5 2 570J2K HW X19 Main Menu ...

Page 23: ...er to set the IP address for control port Netmask This Parameter allows the user to set the Netmask for control port Gateway This parameter allows the user to set the Gateway for control port Please note the control port is only used when the 570J2K HW X19 is used in the S570FR 5 1 3 Data Port Configuration IP Address This parameter allows the user to set the IP address for data port Netmask This ...

Page 24: ...l bitrate transmitted on this output Data port in kbps Rx Frame Count This parameter displays the received Rx frames on this Ethernet port Rx CRC Error Frame Count This parameter displays the received Rx frames with CRC errors on this Ethernet port Rx Undersized Frame Count This parameter displays the received Rx undersized frames on this Ethernet port Rx Oversized Frame Count This parameter displ...

Page 25: ...tem Tab Part 3 5 1 5 Temperature Monitor Temperature This field monitors the current temperature of module 5 1 6 Card Control Load Factory Config This control is used to load factory configuration to each encoder Reboot Card This control allows the user to perform a soft reboot on the encoder ...

Page 26: ...ntrol port MAC address Export Product License File This parameter exports the product license key file Import Product License File This parameter allows the user to upload the product license file 5 2 2 Product Features Supported Product Feature Name This parameter returns the product features supported on this card It should display following feature names J2K ENCODER up to 12 encoders can be ena...

Page 27: ...link can handle up to 270Mbps If a HD input is provided the signal will be clipped If the Input select is configured to HD the max encapsulation on the link can handle up to 1 5Gbps If a 3G input is provided the signal will be clipped When the input select is configured to 3G the max encapsulation on the link can handle up to 3Gbps Video Standard Detected This parameter displays the current video ...

Page 28: ...SY IP Output Control Tab 5 4 1 Configuration Processing Mode This dropdown menu allows the user to select the processing mode which can be Encode or Disable 5 4 2 IP Output Control IP Output Enable This field allows the user to enable or disable the IP output This control is configurable per SFP output port ...

Page 29: ...ows the user to define the destination UDP port IP Output Time to Live This field allows the user to define the output time to live IP Output DSCP This field allows the user to define the output DSCP 5 4 3 IP Output Advanced Control AES Encryption This control allows the user to control AES Encryption The AES Encryption control allows the user to encrypt the encoded output or disable the AES Encry...

Page 30: ...M Sources IGMPV3 SSM Src 1 6 IP Address This parameter allows the user to set IP addresses which will be used while forming the source filter SSM sources for IGMPV3 communications Figure 5 10 WebEASY IP Input Control Tab Part 2 5 5 3 Input SFP Port Selection Main SFP Port Selection This dropdown menu allows the user to assign an Input Data Port as the Main Data Port The main data port will accept ...

Page 31: ...n menu allows the user to enable disable the Gratuitous ARP Gratuitous ARP Address This control allows the user to set the IP address used for Gratuitous ARP 5 6 ENCODER CONTROL Figure 5 11 WebEASY Encoder Control Tab Part 1 5 6 1 Encoder Configuration Source Selection This dropdown menu allows the user to select the source for encoder Possible options are SDI or IP Input SMPTE 2022 6 ...

Page 32: ...the PMT to reflect HDR10 Total TS Bit Rate This parameter allows the user to define the total TS bitrate in kbps Note Card will adjust the bitrate for video and other pids based on these settings For Enc J2K the range is from 50000 to 300000kbps Max Video Bit Rate This parameter reflects the maximum video bitrate used on the encoder 5 6 2 Encoder Audio Output Control Audio Number Of Channels This ...

Page 33: ...ame This control allows the user to define the program name Provider name This control allows the user to define the provider name Service Type This drop down menu allows the user to choose the service type Network ID This parameter allows the user to set the network ID of origin 5 6 4 Compliance Compliance Mode This dropdown menu allows the user to select the encoder compliance mode The available...

Page 34: ...of input stream which could be multicast or unicast Protocol Status This parameter reflects the input protocol It will reflect unknown UDP or RTP AES Encryption Detected This parameter displays if the stream has AES Encryption or not Received Ethernet Bandwidth This parameter displays the received Ethernet Bandwidth for each input stream 5 7 2 Input IP Packet Monitor IP packet Drop Count This para...

Page 35: ...cted with a red status If a fault is inactive it is reflected as a green status Port Link Status SFP1 This status highlights Data 1 port status If the port is up the status will be inactive green If the port is down the status will be active red Port Link SFP1 Trap This control allows the user to enable trap receiving when the port 1 is down and an associated correction trap when the port is up Po...

Page 36: ...tus will be active red Port Link SFP4 Trap This control allows the user to enable trap receiving when the port 4 is down and an associated correction trap when the port is up 5 9 INPUT NOTIFY Figure 5 15 WebEASY Input Notify tab 5 9 1 Encoder Input Notification Video Traps This control allows the user to enable or disable video presence related traps Video Faults This control allows the user to ch...

Page 37: ...nd configured with the required network addresses for the control port it can be completely configured using the web interface For doing this simply type the IP address of the control port of the 570J2K HW X19 module in the web browser Note Computer must be on the same Subnet in order to have communication with the module Figure 6 1 WebEASY Login Menu Login and password is root and evertz respecti...

Page 38: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page 28 Revision 1 0 Figure 6 2 570J2K HW X19 Main Menu ...

Page 39: ...Address This Parameter allows the user to set the IP address for control port Netmask This Parameter allows the user to set the Netmask for control port Gateway This parameter allows the user to set the Gateway for control port Please note the control port is only used when the 570J2K HW X19 is used in the S570FR 6 1 3 Data Port Configuration IP Address This parameter allows the user to set the IP...

Page 40: ...ays the Total bitrate received on this Data port in kbps Transmitted Data Ethernet Total Bitrate This parameter displays the Total bitrate transmitted on this output Data port in kbps Rx Frame Count This parameter displays the received Rx frames on this Ethernet port Rx CRC Error Frame Count This parameter displays the received Rx frames with CRC errors on this Ethernet port Rx Undersized Frame Co...

Page 41: ...This button allows the user to reset the Ethernet monitor statistics Figure 6 5 WebEASY System Tab Part 3 6 1 5 Temperature Monitor Temperature This field monitors the current temperature of module 6 1 6 Card Control Load Factory Config This control is used to load factory configuration settings on the unit Reboot Card This control allows the user to perform a soft reboot on the decoder ...

Page 42: ...ntrol port MAC address Export Product License File This parameter exports the product license key file Import Product License File This parameter allows the user to upload the product license file 6 2 2 Product Features Supported Product Feature Name This parameter returns the product features supported on this card It should display following feature names J2K ENCODER up to 12 encoders can be ena...

Page 43: ...user can select the following modes SDI SD SDI HD 3G SDI When configured to SD the max encapsulation on the link can handle up to 270Mbps If an HD input is provided the signal will be clipped If the Input select is configured to HD the max encapsulation on the link can handle up to 1 5Gbps If a 3G input is provided the signal will be clipped When the input select is configured to 3G the max encaps...

Page 44: ...d Reserved for future use 6 4 2 Genlock Genlock Reference This parameter allows the user to specify the input genlock source The options include frame reference input 1 or input 2 Detected Genlock Reference This will display the detected genlock reference If no reference is found this parameter will reflect unsupported Default Genlock Reference Please set this to NTSC if the expected source freque...

Page 45: ... 1 to 9 H Phase This control allows the user to set the horizontal phase default is 0 V Phase This control allows the user to set the vertical phase default is 1 Please note each decoder output has an independent H and V phase configuration 6 5 IP OUTPUT CONTROL Figure 6 9 WebEASY IP Output Control Tab ...

Page 46: ... Output Source UDP Port This field allows the user to define the output source UDP port number IP Output Destination IP Address This parameter allows the user to define the destination IP address IP Output Destination UDP Port This field allows the user to define the destination UDP port IP Output Time to Live This field displays the IP output time to live IP Output DSCP This field displays the IP...

Page 47: ...put IP address multicast address they want to receive Input IP Port Number This parameter allows the user to select the input UDP port number Input IGMPV3 Mode This parameter allows the user to include exclude input configured SSM Sources IGMPV3 SSM Src 1 6 IP Address This parameter allows the user to set IP addresses which will be used while forming the source filter SSM sources for IGMPV3 commun...

Page 48: ... The backup data port will accept traffic and provide it to the decoder core based on the fail over state and priority configuration 6 6 4 IP Input Advanced Control AES Decryption This dropdown menu allows the user to enable AES de encryption Alternatively if the source isn t encrypted the user can set AES decryption to disable 6 6 5 ARP Control Gratuitous ARP This dropdown menu allows the user to...

Page 49: ...me read from the Evertz private service descriptor 79 from the PMT PSD Network ID This monitor returns the network id read from the Evertz private service descriptor 79 from the PMT 6 7 2 Decoder Input Program Control Program Tuning Mode This parameter allows user to select the program tuning mode of the decoder Auto PID Select automatically tunes to the incoming transport stream When Manual PID S...

Page 50: ...Select This control allows the user to configure the required PCR PID This control is only applicable when the programTuningMode is set to manualPidSelect VANC PID Select This control allows the user to select the VANC PID which decoder will decode This control is only applicable when the programTuningMode is set to manualPidSelect Audio PID Select 1 4 This control allows the user to select the re...

Page 51: ...in access of 30ms Jitter tolerance adds further resilience to the input detection Codec Latency Reserved for future use Decoder Up time This control returns a string representation of the time from last restarting the decoder It is represented similar to xxxx day s yy hrs zz min aa sec Internally it is a 31 bit unsigned integer reflecting seconds which will provide for up to 3100 days of operation...

Page 52: ...vailable options include Equal Priority for Fail Over Priority to Main Port or Priority to Backup Port Fail Over Priority Equal Both the main and backup ports have equal priority If the Main path has no traffic the fail over redundancy model will fail over to backup The input path will remain on backup even if the main path returns as both have equal priority If the backup path has no traffic the ...

Page 53: ... and backup path and is also used to account for jitter along the path The playout delay is user configurable from 0 to 1000ms Smoother The Smoother control enables Jitter smoothing Playout Status The playout status highlights which path is currently being used It will reflect Main Backup or Merged 6 8 IP INPUT MONITOR Figure 6 15 WebEASY IP Input Monitor Tab ...

Page 54: ...cts the total bit rate received for the specified multicast stream unit is kbps Received NULL Packet Bitrate This monitor shows total NULL packet bitrate for multicast stream specified Number of PID in TS This monitor shows the total number of PIDs in the TS Loss Sync Count This monitor shows the total count of sync loss CC Error Count This monitor shows the total count of continuity counter CC er...

Page 55: ...hts the program number for the encoded transport stream PMT PID This parameter highlights the PMT PID PCR PID This parameter highlights the PCR PID Num Video Streams This monitor returns number of video streams in this program Num Audio Streams This monitor returns the number of audio streams in this program 6 9 2 Program Video Monitor For Decoder 1 9 Video PID Num This monitor returns the PID whi...

Page 56: ... be initiated Received Bandwidth Threshold Reserved for engineering use 6 10 2 System Notify Temperature Traps This control allows the user to turn On Off the Temperature Trap Temperature Faults This control checks whether a fault is currently active red or inactive green Port Link Status SFP1 This status highlights Data 1 port status If the port is up the status will be inactive green If the port...

Page 57: ...SFP4 This status highlights Data 4 port status If the port is up the status will be inactive green If the port is down the status will be active red Port Link SFP4 Trap This control allows the user to enable trap receiving when the port 4 is down and an associated correction trap when the port is up 6 11 DECODER NOTIFY Figure 6 18 WebEASY Input Notify Tab 6 10 1 Decoder Notification For Decoder 1 ...

Page 58: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page 48 Revision 1 0 This page left intentionally blank ...

Page 59: ...rrent firmware version and upload the latest firmware Figure 7 1 Figure 7 1 WebEASY Upgrade Button on Top Menu Bar Selecting the Upgrade tab will take the user to Figure 7 2 where the current firmware version is shown Should the firmware version be outdated the user needs to download the firmware image file Figure 7 2 WebEASY Firmware Upgrade Menu Click choose file and browse to locate image file ...

Page 60: ...570J2K HW X19 Multi channel J2K Encoder Decoder Page 50 Revision 1 0 Figure 7 3 WebEASY Firmware Upgrade Menu ...

Reviews: