background image

 

 

 

INFORMATION TO USERS IN EUROPE 

 

NOTE 

 

CISPR 22 CLASS A DIGITAL DEVICE OR PERIPHERAL 

 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 

to the European Union EMC directive.  These limits are designed to provide reasonable protection 

against harmful interference when the equipment is operated in a commercial environment.  This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 

accordance with the instruction manual, may cause harmful interference to radio communications.  

Operation of this equipment in a residential area is likely to cause harmful interference in which case the 

user will be required to correct the interference at his own expense. 

 

 

 

INFORMATION TO USERS IN THE U.S.A. 

 

NOTE 

 

FCC CLASS A DIGITAL DEVICE OR PERIPHERAL 

 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 

to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment.  This equipment generates, 

uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio communications.  Operation of this 

equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense. 

 

WARNING 

 

Changes or Modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s 

authority to operate the equipment. 

 

Use of unshielded plugs or cables may cause radiation interference.  Properly shielded interface cables 

with the shield connected to the chassis ground of the device must be used. 

 

 

 

 

 

 

EN60065 

Safety 

 

 

EN504192 2005 

Waste electrical products should not be 

disposed of with household waste. 

Contact your Local Authority for recycling 

advice 

EN55103-1: 1996 

Emission 

EN55103-2: 1996 

Immunity 

Summary of Contents for 570ASI-X19-10GE2

Page 1: ...tz Microsystems and is intended solely for the use of purchasers of the 570ASI X19 10GE2 series product Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 570ASI X19 10GE2 series product Due to on going research and development features and specifications in this manual are subject to change without notice All rights reserved No part of t...

Page 2: ...This page left intentionally blank ...

Page 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Page 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Page 5: ... offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically undertaken in the Ever...

Page 6: ...570ASI X19 10GE2 Series User Manual Page ii This page left intentionally blank ...

Page 7: ... FIBER 6 3 4 HARDWARE INSTALLATION 6 4 WEB INTERFACE 7 4 1 SYSTEM 9 4 1 1 Control Port Configuration 10 4 1 2 Data Port Configuration 10 4 1 3 Data Port Monitor 10 4 1 4 SFP Monitor 10 4 1 5 Temperature Monitor 11 4 1 6 Configuration Management 11 4 1 7 Card Control 12 4 1 8 Genlock 12 4 1 9 RPC Control 12 4 2 PRODUCT FEATURES 12 4 3 IP INPUT CONTROL 13 4 3 1 MPPM Control 14 4 3 2 Stream Selection...

Page 8: ...dio Groups 1 4 23 4 6 5 ANC 23 4 6 6 SMPTE 2110 RTP Payload Type 23 4 7 DIN OUTPUT CONTROL 24 4 7 1 Output Control 24 4 7 2 Phase Adjustment 24 4 8 SYSTEM NOTIFY 25 4 8 1 System Monitoring Control 25 4 8 2 Board Notify 25 4 8 3 Port Link Notify 25 4 9 ASI INPUT NOTIFY 26 4 9 1 ASI Input Alarm Control 26 4 9 2 ASI Input Notification 26 4 10 IP INPUT NOTIFY 27 4 10 1 IP Input Notify Controls 27 4 10...

Page 9: ...uct Features 12 Figure 4 8 WebEASY IP Input Control Part 1 of 2 13 Figure 4 9 WebEASY IP Input Control Part 2 of 2 16 Figure 4 10 WebEASY DIN Input Control 18 Figure 4 11 WebEASY PTP and Master PCR Control 19 Figure 4 12 WebEASY IP Output Control 21 Figure 4 13 WebEASY DIN Output Control 24 Figure 4 14 WebEASY System Notify 25 Figure 4 15 WebEASY ASI Input Notify 26 Figure 4 16 WebEASY IP Input No...

Page 10: ...570ASI X19 10GE2 Series User Manual Page vi This page left intentionally blank ...

Page 11: ...lized and customers have the option of selecting any of the 2 ports to input output IP streams 570ASI APP IPG This APP enables 6x6 conversions of SDI to SMPTE ST 2022 6 2110 SMPTE ST 2022 6 2110 to SDI ASI to IP and IP to ASI Up to 6x 10GbE ports can be utilized and customers have the option of selecting any of the 6 ports to input output IP streams The 570ASI X19 10GE2 supports hitless merge for ...

Page 12: ...570ASI X19 10GE2 Series User Manual Page 2 This page left intentionally blank ...

Page 13: ...0m 1 5 Gb s 350m 270 Mb s Return Loss 15dB up to 0 5 GHz 10dB up to 3 GHz 2 3 IP INPUT Ethernet Interface 570ASI APP ASI 2x 10GbE SFP SFP 570ASI APP IPG 6x 10GbE SFP SFP Encapsulation MPEG 2 TS over IP Uncompressed SMPTE ST 2022 6 ST 2110 2 4 SERIAL VIDEO ASI OUTPUT Number of Outputs 570ASI APP ASI 10x ASI 570ASI APP IPG 6x SDI Connector DIN Rise and Fall Time Per SMPTE spec 2 5 IP OUTPUT Ethernet...

Page 14: ... Bulk IP ASI media processor up to 12x 10GbE interfaces using SFP cages SFPs sold separately A 570ASI APP must be purchased with each card 2 9 ORDERING OPTIONS 570ASI APP ASI 570ASI X19 App to enable 10x ASI in and 10x ASI out IP Gateway up to 2x 10GbE ports 570ASI APP IPG 570ASI X19 App to enable 6x6 conversions of SDI ASI SMPTE ST 2022 6 and ST 2110 up to 10x 10GbE ports 2 10 SFP MODULES SFPTR R...

Page 15: ...NT PLATE The front of the 570ASI X19 10GE2 is equipped with 12x SFPs ports capable of passing 10Gb of data per port 3 2 BACK PLATE The rear plate of the 570ASI X19 10GE2 is equipped with 20 Mini Din connectors The first 18 are 3G HD SD bidirectional on the fly configurable copper coax ports and the last 2 are currently not used ...

Page 16: ...h 570ASI X19 10GE2 installed in frame Before handling the card it is important to minimize the potential effects of static electricity It is therefore recommended that an ESD strap be worn Locate 2 adjacent vacant slots on the chassis Unpack the 570ASI X19 10GE2 and separate the rear panel from the main card Locate on the rear of the rack the two slots and remove the blanking panels Insert the rea...

Page 17: ... of the 570ASI X19 Figure 4 1 WebEASY Login Menu For login and password type in customer Upon entering the correct credentials the user will be directed to the main User Interface that displays display the following information Figure 4 2 WebEASY Top Navigation Bar Top Navigation Bar o Product Name Displays the product Name o Refresh Manually refreshes the user s configuration o Auto Refresh Autom...

Page 18: ...user is able to monitor configure Main Tab Middle section of the interface displays all the fields for the item selected from the side menu These menu tabs and fields will be fully described in the following sections Note Due to the size of the certain menu tabs screen tab images will be broken into multiple images ...

Page 19: ...570ASI X19 10GE2 Series User Manual Page 9 4 1 SYSTEM Figure 4 4 WebEASY System Part 1 of 2 ...

Page 20: ...d Data Ethernet Total Bitrate This field displays the total bitrate in Kbps that has been received Transmitted Data Ethernet Total Bitrate This field displays the total bitrate in Kbps that has been transmitted Rx Frame Count Counter for good frames received on the trunk Rx CRC Error Frame Count Counter for CRC Error frames received on the trunk Rx Undersized Frame Count Counter for undersized fra...

Page 21: ...e that when the user saves a configuration it saves all subscribed routes that were present on the card Keep in mind that when this configuration is loaded back on the 570ASI Magnum reconnects to the card it will push new routes to the 570ASI Magnum SDVN does not tear down routes it does not know exist that may be present on the 570ASI These routes can potentially create over subscription problems...

Page 22: ...External Genlock Ref 1 External Genlock Ref 2 PTP Master PCR Free Run Detected Genlock Reference This control displays the detected genlock reference The possible genlock references include unsupported absent PAL NTSC Default Genlock Reference This control allows theuser to configure genlock reference rate The possible genlock references include NTSC and PAL 4 1 9 RPC Control For Main and Backup P...

Page 23: ...570ASI X19 10GE2 Series User Manual Page 13 4 3 IP INPUT CONTROL Figure 4 8 WebEASY IP Input Control Part 1 of 2 ...

Page 24: ...nput stream IP Input Sync Detect This field indicates whether the IP input is synced with the card 4 3 3 SMPTE 2110 2022 6 Receiving Buffer Mode For IP Inputs 1 to 6 SDI Output Buffer Mode This field allows the user to set the virtual SDI output mode Possible options are Low Latency Engineering Test Mode Frame Buffer Error Concealment Mode and Line Buffer H V Offset Mode SDI Output H Offset This c...

Page 25: ... X19 10GE2 Series User Manual Page 15 IGMPV3 SSM Src 1 6 IP Address This parameter allows the user to set IP addresses which will be used while forming the source filter SSM sources for IGMPV3 communications ...

Page 26: ...570ASI X19 10GE2 Series User Manual Page 16 Figure 4 9 WebEASY IP Input Control Part 2 of 2 ...

Page 27: ...ANC IP Input for SFPP 1 to 6 IP Input Status This parameter indicates if the selected input stream type MPPM mode and SFP selections have enabled usage of this audio group s IP address Audio Group IP Address This parameter allows the user to select the input IP address multicast address for the audio that they want to receive Audio Group UDP Port This parameter allows the user to select an input U...

Page 28: ... counter ASI Packet Size This field displays the transport stream packet size in bytes Received Total TS Bitrate This field displays the total bitrate for the multicast stream specified Received NULL Packet Bitrate This field displays the total NULL packet bitrate for multicast stream specified Number of PID in TS This field displays the total number of Packet IDs in the transport stream Loss Sync...

Page 29: ...R Control PTP or Master PCR Selection This parameter allows the user to select the reference as either PTP or Master PCR Main Data Port Select This dropdown allows the user to select the main data port select between SFP 1 to SPF 6 Backup Data Port Select This dropdown allows the user to select the backup data port select between SFP 1 to SPF 6 ...

Page 30: ...omain Number This control allows the user to set the domain number 4 5 3 Master PCR Control IP Address This field allows the user to set the IP address from which to obtain the Master PCR time reference UDP Port Number This field allows the user to set the UDP port number from which to obtain the Master PCR time reference PCR PID This parameter allows the user to set the expected PCR PID PCR Prese...

Page 31: ...570ASI X19 10GE2 Series User Manual Page 21 4 6 IP OUTPUT CONTROL Figure 4 12 WebEASY IP Output Control ...

Page 32: ...nable This parameter is used to enable or disable an output Source IP Address This parameter allows the user to define source IP address Source UDP Port This parameter allows the user to define source UDP port Destination IP Address This parameter allows the user to define destination IP address Destination UDP Port This parameter allows the user to define destination UDP port Time to Live This pa...

Page 33: ...This parameter allows the user to enable or disable Redundant Packet Transmission 4 6 4 Audio Groups 1 4 For IP Outputs 1 to 6 IP Output Enable This parameter allows the user to enable the SMPTE 2110 audio Destination IP Address This parameter allows the user to set output IP address multicast address Destination UDP Port Number This parameter allows the user to set the output UDP port number 4 6 ...

Page 34: ...n This control allows the user to select which input channel is to be the source for the DIN output SDI Output A V Sync Mode This control allows the user to choose the synchronization mode for the audio and video Options are Bypass Timestamp Match Latency Match Output Timing Reference This control allows the user to select the timing reference for the selected Din output Options are Genlock or Flo...

Page 35: ...ble the Temperature Trap Temperature Faults This temperature status is highlighted with this parameter If a fault is active the temperature exceeds the temperature threshold it is reflected with a red status If a fault is inactive it is reflected as a green status 4 8 3 Port Link Notify For SFP1 to 6 Port Link Status SFP This status highlights Data port status If the port is up the status will be ...

Page 36: ...s the Closed Captioning Error Threshold before an alarm is sent Time Frame 1 to 600 This control sets the period in seconds over which the threshold can surpass 4 9 2 ASI Input Notification For DIN input 1 to 6 ASI Input Traps This parameter is used to turn input traps On and Off ASI Input Faults This control checks whether an input fault is currently present or not ...

Page 37: ...inimum Received Bandwidth Threshold This control sets the minimum amount of bandwidth that must be present before an alarm is sent 4 10 2 IP Input Notifications For IP input 1 to 6 IP Input Traps This parameter is used to turn input traps On and Off IP Input Faults This control checks whether an input fault is currently present or not ...

Page 38: ... Destinations Add Trap Destination This parameter allows the user to enter a new SNMPv1 trap destination IP address Trap Destination 1 to 10 These Parameters show the current SNMPv1 trap destination IP address Clear Button Each of these buttons clear the IP address displayed for its respective trap destination ...

Page 39: ...f the web page for the 570ASI X19 10GE2 there is a tab labeled Upgrade The Upgrade tab is used to check current firmware version and upload the latest firmware Figure 5 1 WebEASY Upgrade Button on Top Menu Bar Selecting the Upgrade tab will open a new window as shown in Figure 5 2 where the current firmware version is shown Should the firmware version be outdated the user will need to download the...

Page 40: ...e 30 Figure 5 3 WebEASY Firmware Upgrade Menu Once selected click Open Step 1 to advance to next step Click Upgrade Step 2 and watch progress bar for status Once completed the device will automatically restart Step 1 Step 2 570ASI X19 10GE2 ...

Reviews: