![evertz 2430RX-J2K-IP Series User Manual Download Page 12](http://html.mh-extra.com/html/evertz/2430rx-j2k-ip-series/2430rx-j2k-ip-series_user-manual_2445191012.webp)
2430RX-J2K-IP
JPEG2000 to HDMI Converter User Manual
Page - 4
Revision 0.1
2.2.
HARDWARE INSTALLATION
Note: SFP’s must be ordered separately
To successfully install the 2430RX-J2K-IP the user will require the following:
1. Unused IP address on the network or a DHCP server.
2. VistaLINK
®
PRO Server IP address.
Before handling this device it is important to minimize the potential effects of static electricity. It is
therefore recommended that an ESD strap be worn.
Ensure that the device is powered up and the green LED is on. Connect the device via the COM port
using a 9-pin Serial Cable., Connect the Female end of the serial cable to the serial port of your PC.
Connect the the opposing Male end to the 9-Pin connector on rear of unit. In order to begin
configurations ensure the below settings are configured properly:
Baud: 115200
Data: 8-BIT
Parity: none
Stop Bits: 2
Flow Control: none
Open TeraTerm (if using Windows XP or older open Hyper Terminal) to make the required changes to
the IP address on the card. Use the login
customer
and password
customer.
2.2.1. Inband Control Configuration
This sub-menu enables the user to configure the settings for unicast traffic forwarding. The user should
be aware that once this has been enabled, the control port will not be active and all control will be made
via Inband Data connection. The following steps should be followed to ensure proper confirguration:
1) Connect COM port to 2430RX-J2K-IP
2) Login when prompted: username
customer
password
customer
3) Select Option (5) For inband control
3) Select (1) for Enable
4) Select (Y) to confirm
5) Select (X) to save and exit from the 2430RX-J2K-IP main menu
After the Inband control configurations have been enabled, wait for the unit to reboot.