background image

ambient illumination is lower than preset value. If a person moves within or across the device field of vision, 

a trigger radio signal will be transmitted e.g. to turn on the connected lightings for better illumination.

When the detector is first time powered up it is not included in a Z-Wave network and has no Associations. 

For Inclusion or setting an Association, the device has to be brought in the relevant mode and the 

inclusion/exclusion switch has to be clicked fast three times. The sensor supports two association groups, 

the first for one device (alarm) and the second for up to five devices (home automation).

Wakeup Intervals - how to communicate with the device?

W

 This device is battery operated and turned into deep sleep state most of the time to save battery 

life time. Communication with the device is limited. In order to communicate with the device, a static 

controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices 

and store commands that can not be received during deep sleep state. Without such a controller, 

communication may become impossible and/or the battery life time is significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup 

Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with 

the desired wakeup interval and the node ID of the controller. If the device was included by a static 

controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff 

between maximal battery life time and the desired responses of the device.

Tripple click on the little button behind the battery cover or a detected action by the sensor will wake up the 

device and keep it awake.

It is possible to set the node ID to 255 to send wakeup notifications as broadcast. In this mode device takes more time to 

go to sleep and drains battery faster, but can notify all it's direct neighbors about a wakeup.

Node Information Frame

NI

 The Node Information Frame is the business card of a Z-Wave device. It contains information 

about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed 

by sending out a Node Information Frame. Beside this it may be needed for certain network operations to 

send out a Node Information Frame.

Tripple click on the little button behind the battery cover or a detected action by the sensor sends a Node 

Information Frame.

Associations

A

 Z-Wave devices control other Z-Wave devices. The relationship between one device controlling 

another device is called association. In order to control a different device, the controlling device needs to 

maintain a list of devices that will receive controlling commands. These lists are called  association groups 

and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event 

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 5 

Summary of Contents for EVR HSP02

Page 1: ...he unit sends information to a controller or any other associated Z Wave device Up to 5 devices can be controlled from this device The sensor is a battery powered device which is in sleeping mode unless an action is detected After a programmable sleeping time the device wakes up and sends a status information After this the unit goes back to sleeping mode The battery can be changed without unscrew...

Page 2: ... The recommended position for a PIR Detector is in the corner of a room mounted at a height between 1 8 and 2 0 m At this height the detector will have a maximum range of up to 9 m with a field of view of 110 The monitoring range can be set up with PCB pattern ...

Page 3: ... the battery cover which is also the mount plate and the screws Further fix the sensor with mount plate like shown in the picture b For mounting the sensor in a corner use the lateral holes of the mount plate Further fix the sensor with mount plate like shown in the picture ...

Page 4: ...rk Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Make sure that your Z Wave Controller is in the Inclusion Exclusion Mode Click the little button behind the battery cover fast three times to confirm the process Operating the device The Motion Detector is designed with two detecting sensors Passive Infra Red PIR senso...

Page 5: ...d with the desired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device Tripple click on the little button behind the battery cover or a detected action by the sensor will wake up...

Page 6: ...tion Groups 1 Devices controlled by open close events max nodes in group 5 Technical Data Battery Type 1 CR2 Explorer Frame Support No SDK 5 02 pl2 Device Type Slave with routing capabilities Generic Device Class Binary Sensor Specific Device Class Routing Binary Sensor Routing No FLiRS No Firmware Version 1 3 ...