Troubleshooting

Table below lists typical problems encountered:

ymptom

loodhght does  not

turn on for 5 seconds

after power is

connected.

annot carry  out

inclusion and

association

t  as  es on

and off

ave  contro ler

cannot communicate

with the  unit

oodlight remains  on

oss  e  ause

ower is not

connected properly

oodlight alrea  y

paired to another

Z-Wave Controller.

ut o  range.

etector

triggered by

unknown heat

source.

ecommen  at on

ec 

wall switch is on.

Confirm wiring is correct.

Check  supply breaker / fuse.

e  orm a  actory reset.

e unit's ux sensor is being tnggere  o  y

reflected li  ht

2.

2.

elocate the contro erc  ser to  e unit.

Install a Z-Wave  repeater such as  smart

plugs or other AC  devices  that can operate

as a Re  ater.

heck time setting

Cover  its PIR  Detector with black insulating

tape. If after the timer expires  and  the

floodlight turns off this indicates that the PIR

Detector can  see  a  moving heat source e.g:

radiator, heater, boiler outlet. open window,

open exterior door or moving branches  or

bushes  retaining heat from the daytime

eriod.

Manual Inclusion/Exclusion

The  table below lists the several  steps  involved when adding or removing the unit from the

Z-Wave network.

Action/Status

No node ID

Auto Inclusion

Manual Inclusion

Exclusion

Factory Reset

(This procedure

should only be used

when the controller

is inoperable.)

Description

The  Z-Wave  Controller does  not allocate a node

ID to the unit.

The  power is applied for the first time and no

node  ID has  been stored in the module, or after

executing reset.

1.

2.

1.

2.

1.

2.

3.

Put the Z-Wave  Controller into inclusion

mode.
Press  the tamper switch 3 times within 1.5

seconds  to put the unit into inclusion mode.
Put the Z-Wave  Controller into exclusion

mode.
Press  the tamper switch 3 times within 1.5

seconds  to put the unit into exclusion  mode.

Press  the tamper switch 3 times within 1.5

seconds  to put the unit into exclusion  mode.

Within 1 second  of step  1, press  the tamper
switch again  and  hold until LED  is off (about

5 seconds .

Node ID is excluded.  The device reverts to

LED indication

2-second  on. 2-second  off

for 2 minutes.

LED  blinks rapidly during

Inclusion, LED  stops

blinking when Inclusion is

com  lete.

LED  blinks rapidly during

Inclusion, LED  stops

blinking when Inclusion is

complete

factory default state and will be in
auto-inclusion  mode for 4  minutes.

x  Failed  or successful  results  in including/excluding the ID can  be viewed on the Z-Wave  Controller.

9

Summary of Contents for EH403

Page 1: ...el and the timer can be set throughknobs on thedevice itself When added intoa Z Wave network EH403 communicatesdirectlywithotherend devices such as smart plugs orto reportdirectlytoa Z Wave controller usually a gateway It alerts the controllerwhen motionis detectedand throughZ Wave commands the controllercan remotely turn on offthe floodlightat any time and be able to configure its lux level and t...

Page 2: ... the cable plug to the wall socket to powerup the unit WARNING be careful not to touch any exposed wire contactsto preventelectrical shock 4 The Link LED will start to blink slowly with2 second on 2 second off for2 minutes which shows the unitdoes notbe paired 5 Within 30 seconds put the Z Wave Controller into inclusion mode 6 The Inclusion process should be completed when the Link LED stops blink...

Page 3: ... directly towards tho detector PIR less sensitive PIR moresensitive For the best results mountthe floodlightontonormalbrickwork1 8 20m above the ground At this height the unitWilldetect movement withinits 110degrees fan shaped detectionpatternup to8m dependingon adjustment 2 Topview 4 Side view SAFETY PRECAUTION DO NOT install when it is raining Isolatethe powersupply beforeInstallation Ensure tha...

Page 4: ... wall switch to allow easy controlof the AC POVER N N 5 Connect the mains power supply to the pre wiredcable providedwiththe fittingas shown above If the connection is made outdoorsa suitablewaterproofIP box must be used tomake theconnections Follow exactly the wire colors as below BROWN Live wire to the mains live connection via a wall switch BLUE Neutral wire to the mains neutralconnection GREEN...

Page 5: ...off before movingagain to test 2 If necessary tiltthe floodlightto achieve desired result The floodlightmay be tilted downwards by up to 300to light the area directly under it Tilting by more than 300may cause issues with the lux sensor as light reflectedback from the area under the floodlight may switch the lux sensor to daylight mode hence turningthe floodlightoff 3 When you are satisfied with t...

Page 6: ...ected to a Z Wave controller the manualsettingswillbe overwrittenby the settings throughtheZ Wave controller Operation Z Wave Group The unit supports either one of twoZ Wave Association Groups Group 1 Association with 1 Controller node Group 2 Association with4 nodes i e end devices such as smartplugs and otherlighting controllers This allows the PIR detectoron the unittotransfer commands directly...

Page 7: ...iggerOFF Groupf Switch BinaryRoport Group f Bastc Set Off Group2 Z Wave commands notrfication Remark otircation irst owor p roup evtce eset oca oti cation rou Installer Icon User Icon Sensor NotificationDevice Sensor NotificationDevice T e Home Secunt Home Securit Association Command Class Group Max Node 1 2 4 Version Protocol Library Protocol Version Manufacturer Manufacturer ID ox0060 AGI Associ...

Page 8: ...Parameter Size 3 2 Range 30 200 Range Default 50 Default 0 1440 minutes 0 0ff 4 MultilevelSensor Reads back the lux level measured Tolerance of 30 lux Level above 250 willbe read back as 250 Sensor Type Precision Scale ox03 1 CommandClasses Size 2 The modulesupports Command Classes including COMMANDCLASS ZWAVEPLUS INFO V2 COMMAND CLASS ASSOCIATION vr COMMAND CLASS ASSOCIATION GRP INFO COMMAND CLAS...

Page 9: ...teps involved when adding or removing the unitfrom the Z Wave network Action Status No node ID Auto Inclusion Manual Inclusion Exclusion FactoryReset This procedure should only be used when the controller is inoperable Description The Z Wave Controllerdoes notallocate a node ID to the unit The power is applied for the first timeand no node ID has been stored in the module or after executingreset 1...

Reviews: