Mounting the Unit
Choosing the location
The recommended location for tho noodhght is outside the house under the eaves or
other shaded areas where it js not directly exposed to sunltght.
Do not aim its PIR detector facing a window or direct sunlight. otherwise poor
triggering response may occur,.
- Avoid aiming the PIR Detector at pools. heating vents. air conditioners or objects that
may change temperature.
- Avoid aiming the PIR Detector at trees or shrubs or where the movement of pets or
animals may be detected
- Where possible. mount the unit so that the path of an intruder would cut across the
fan pattern rather than directly towards tho detector.
PIR less sensitive
PIR more sensitive
For the best results. mount the floodlight onto normal brickwork 1
8—2
0m above the
ground, At this height. the unit Will detect movement within its 110 degrees fan-shaped
detection pattern up to 8m depending on adjustment.
2
Top view
4
Side view
SAFETY PRECAUTION
DO NOT install when it is raining,
Isolate the power supply before Installation.
Ensure that local Wring and Building regulations are complied with.
The unit is supplied with a pre-wired supply cable this must be used and must not be
removed.
Ensure that the power supply is protected by a 6amp circuit breaker or 5amp fuse.
Ensure minimum distance of 2.0m away from liahted objects.
The unit must be installed vertically with the PIA at the bottom of the unit.
The unit can be corner mounted if preferred,
3