Everpure KleenSteam CT Catalog Download Page 1

FoodService

catalog

VOLUME 1

ISSUED  APRIL  15,  2011

Summary of Contents for KleenSteam CT

Page 1: ...FoodService Catalog VOLUME1 ISSUED APRIL 15 2011...

Page 2: ...erage and equipment the best it can be Everpure Solutions Offer Consistency Remove or reduce unwanted minerals particulates and chemicals so your water is sparkling clean every time Confidence Everpur...

Page 3: ...d HydroblendTM are used pursuant to an agreement with PWC Enterprises Inc AboutPentairFoodservice Pentair Foodservice is focused on supporting the foodservice market by providing solutions that help o...

Page 4: ...n cm Filter system height 14 4 36 5 18 7 47 5 16 1 41 0 20 7 52 5 18 6 47 1 Filter cartridge diameter 3 7 9 5 3 7 9 50 5 4 13 6 5 4 13 6 6 9 17 5 Typical Capacity gallons litres gallons litres gallons...

Page 5: ...p Wt List Price lb kg gallons litres Claris Head EV4339 21 Yes Yes 3 8 BSP 1 1 0 5 133 00 Claris Head EV4339 23 Yes Yes 3 8 QCF 1 1 0 5 133 00 Claris Head EV4339 25 Yes Yes 1 4 QCF 1 1 0 5 133 00 Clar...

Page 6: ...SO 7 QC71 Single EV9272 41 5 300 0 5 1 9 27 5 x 5 6 x 4 69 9 x 14 0 x 10 1 7 3 2 252 00 ESO 7 EV9607 25 5 300 0 5 1 9 27 5 x 5 6 x 4 69 9 x 14 0 x 10 1 7 3 2 155 00 QC7I Twin ESO 7 QC71 Twin EV9272 22...

Page 7: ...culate along with carbon GAC for the ESO carbon block for the Claris for reducing chemicals such as chlorine There are some differences the key one being how blending is handled The blending of filter...

Page 8: ...ty gpm lpm gallons litres Brewers 0 5 GPM and Under QL2 OCS2 0 5 1 9 3 000 1 2 Gal Pots 11 000 2 L Pots 1 500 5 677 Brewers 0 5 GPM 1 0 GPM QL3 BH2 0 5 1 9 6 000 1 2 Gal Pots 23 000 2 L Pots 3 000 11...

Page 9: ...4 30 5 x 9 7 x 10 2 3 1 4 112 00 QL3 BH2 EV9272 00 3 000 11 356 16 5 x 3 75 x 4 42 0 x 9 7 x 10 2 4 1 8 162 00 QC7I Single MH2 Head EV9272 41 Cartridge EV9613 21 9 000 34 069 27 5 x 5 6 x 4 70 0 x 14...

Page 10: ...on process offers Pre filtration Carbonate hardness adjustment Fine filtration Ion Exchange NEW System Part Number Auto Shut Off Mounting Bracket Connection Rated Capacity Pack Size Ship Wt List Price...

Page 11: ...Attribute Specification Turbidity Must not exceed 0 5 Nephelometric Turbidity Units Taste Odor Free from off tastes and odors Total Chlorine 0 05 ppm Iron Not more than 0 25 ppm Total Alkalinity Not m...

Page 12: ...e filtration technology LVPO F2 Kit System Part Number Rated Capacity Flow Rate Pack Size Ship Wt List Price gpm lpm lb kg gallons litres QCP 1 Single Head EV9107 21 48 16 7 2 30 90 QCP 2 Twin Series...

Page 13: ...n with scale control 2 400 9 080 6 6 2 7 25 50 IN 10 EV9100 06 10 granular activated carbon with scale control and John Guest fittings 2 400 9 080 6 6 2 7 32 30 IN 10 CS EV9100 69 10 100 coconut shell...

Page 14: ...icrobial protection FountainBeverageFiltrationSystem Fountain beveragesare 83 water Up to 1 67 GPM Up to 3 34 GPM Up to 5 0 GPM Coldrink 1 MC2 Coldrink 2 MC2 Coldrink 3 MC2 To maximize filter life and...

Page 15: ...260 25 7 x 24 6 x 5 5 65 3 x 62 5 x 14 0 20 9 0 902 00 98 70 Dual High Flow Coldrink S MC2 EV9337 44 72 000 272 520 37 25 x 36 x 14 25 94 6 x 91 0 x 36 2 70 31 5 3 783 00 Dual High Flow Coldrink M XC2...

Page 16: ...t off valve with integrated sediment prefilter flushing valve and water pressure gauge s High Flow CSR models feature SR X housing with SS IMF cartridge for scale reduction 7CLM replacement filter car...

Page 17: ...00 60 566 2 0 7 6 Coldrink 3 7CLM EV9327 13 10 800 40 882 5 1 19 3 25 6 x 25 75 x 6 0 65 0 x 65 4 x 15 24 31 2 14 2 1 302 40 16 500 62 459 4 0 15 1 24 000 90 850 3 0 11 4 Coldrink 4 7CLM EV9327 14 14...

Page 18: ...mines are most commonly formed when chlorine and ammonia are combined for use as a disinfectant to treat drinking water Why chloramine versus chlorine treatment Chloramines provide longer lasting wate...

Page 19: ...00 13 627 12 75 x 3 25 32 4 x 8 3 6 10 4 5 154 00 Bottled Water Delivery System 83 001 01 8 7 x 7 5 x 3 3 22 1 x 19 1 x 8 4 1 10 4 5 307 00 Faucet Kit EV9820 10 1 1 0 5 99 40 1 2 GPM Flow Control for...

Page 20: ...conditions can produce different results System features include NSF certifications Manifold has inlet water shut off valve with optional integrated sediment prefilter flushing valve and water pressu...

Page 21: ...2 EV9325 03 36 000 136 260 29 3 x 21 x 5 5 74 3 x 53 3 x 14 0 18 8 1 960 00 Insurice Triple PF i40002 EV9325 23 36 000 136 260 30 3 x 25 75 x 6 77 0 x 65 4 x 15 2 23 10 4 1 146 00 Insurice Quad i40002...

Page 22: ...y for Higher Volume Operations High Flow CSR Plus XC2 48 000 18 680 6 7 25 3 Rated chemical filtration capacity Mechanical sediment filtration capacity is dependent on incoming water quality For flash...

Page 23: ...30 x 6 7 65 0 x 76 2 x 17 1 39 17 5 1 246 00 High Flow CSR Triple MC2 w low pressure alarm EV9328 05 27 000 102 195 25 6 x 30 x 6 7 65 0 x 76 2 x 17 1 39 17 5 1 448 00 High Flow CSR Quad MC2 EV9437 1...

Page 24: ...the water No wasted water Conventional RO systems send a considerable volume of waste water to drain during the water extraction process as high as four gallons to drain for every one gallon of pure w...

Page 25: ...eam gives it an edge The Claris XXL has an edge on direct injection steamers where water is sprayed onto a hot plate and converted into steam as opposed to being superheated inside a boiler chamber an...

Page 26: ...eam Up to 1 67 GPM Includes 7CB5 carbon filter SS 10 scale inhibitor cartridge dip tube and two 2 2 lb canisters of ScaleKleen Up to 2 5 GPM Up to 5 0 GPM System Part Number Dimensions H x W x D Ship...

Page 27: ...ScaleKleen Part Number Pack Size Ship Wt List Price lbs kgs ScaleKleen Scale Remover English French Spanish EV9798 31 96 packs case 12 5 4 4 40 ScaleKleen Scale Remover English French Spanish EV9798...

Page 28: ...t Economical solutions are available to control this build up and periodically remove any accumulation System features include l Inhibits limescale build up by dispensing controlled amount of Hydroble...

Page 29: ...Number Description Pack Size Ship Wt List Price lb kg SMARTWORKS Water Test Kit DEV7013 44 Includes instructions disposable TDS meter test strips for hardness pH total alkalinity total chlorine free c...

Page 30: ...0 0 37 9 14 0 53 0 1 2 5 1 0 0 03 13 x 22 x 45 33 0 x 55 9 x 114 3 300 136 1 90 40 8 1 973 00 WS 45 EV9980 11 45 000 12 0 54 4 16 0 60 6 1 2 5 1 5 0 04 37 x 22 x 68 94 x 55 9 x 172 7 335 152 0 125 56...

Page 31: ...e 5 ppm can damage your softening resin To prolong the lifespan of your water softener when these materials are excessively present Everpure recommends a prefilter Also use salt that contains an iron...

Page 32: ...ups of water to the drain for each cup of coffee produced Wastewater to Drain MRS 600HE Systems With an average recovery of 78 the MRS 600HE systems dispose of about 1 4 of a cup of water for each cup...

Page 33: ...rpure Coldrink Series CB20 302E or CB20 312E are suitable pre treatment systems MR 600 MC2 7FS BW Replacement Cartridges Product Part Number Pack Size Ship Wt List Price lb kg MR 600 Cartridge EV9627...

Page 34: ...e blend valve which allows custom tailoring of the dissolved mineral content in the treated water With this feature a controlled amount of raw water is mixed with the reverse osmosis water to create a...

Page 35: ...et Dimensions H x W x D Ship Wt List Price in cm lb kg 1 2 gal 3 gal EV3102 75 1 4 MNPT 15 x 11 x 11 38 1 x 27 9 x 27 9 9 4 1 169 00 4 3 gal 15 gal CH30834 1 1 MNPT 27 x 16 x 16 68 6 x 40 6 x 40 6 20...

Page 36: ...t Outlet Dimensions H x W x D Ship Wt List Price gal litre in cm lb kg 804 023 115 VAC 90 115 2 7 6 3 8 Barb 13 x 10 x 10 33 x 25 4 x 25 4 14 6 4 627 00 804 029 115 VAC 90 115 2 7 6 3 8 Barb 13 x 10 x...

Page 37: ...21 9 5 870 00 Note Contact factory for 230V options ReplacementCartridges Parts Part Number Description PSI Volts List Price 88025 933 237 Water Boost Replacement Pump 60 115 259 00 8025 933 399 Wate...

Page 38: ...Pressure Gauge s Pack Size Ship Wt List Price lb kg Single Head EV9272 41 N Y 3 8 NPT Y N 2 3 1 7 252 00 Twin Parallel Head EV9272 22 Y Y 3 4 NPTG Y Y 1 6 2 7 446 00 Triple Parallel Head EV9272 23 Y...

Page 39: ...T 3 8 NPT Y Y 1 20 9 1 1 061 00 Not shown See REFERENCE section for Manifold System Configurations Ordering Guide High Flow CSR Manifolds System Part Number Scale Reduction Shut Off Valve Mounting Bra...

Page 40: ...42 10 System Part Number Connection Pack Size Ship Wt List Price lb kg CGS 10 Single EV9100 10 3 8 FPT 1 5 2 3 139 00 CGS 12 Dual Series EV9100 12 1 2 FPT 1 8 3 6 227 00 CGS 20 Single EV9100 20 3 8 FP...

Page 41: ...000 34 069 1 17 7 7 126 00 i20002 EV9612 22 7 9 000 34 069 1 17 7 7 111 00 XC2 EV9613 10 X 12 000 45 425 1 23 10 4 123 00 i40002 EV9612 32 X 12 000 45 425 1 23 10 4 126 00 Triple MC2 Kit EV9970 42 7 2...

Page 42: ...ate Reduction Scale Reduction EV9781 12 6 14 6 4 79 30 Sediment Prefilter Cartridges drop ins Model Technology Housing Part Number Pack Size Ship Wt List Price lb kg SO 10 Ion Exchange A 10 11 EV9105...

Page 43: ...ing 7NE 7 EV9607 02 1 5 2 7 150 00 Iron Sulfur Oxidizing 7OF 7 EV9607 0 1 6 2 7 165 00 Chloramine Granular Activated Carbon CC1E 4 x 20 Drop In 15 000 56 775 EV9105 02 1 4 1 8 287 00 System Part Numbe...

Page 44: ...S DC 4000299 11 42 74 x 18 x 24 118 0 x 45 7 x 61 0 1 84 38 1 7 056 00 Homespring California GAC Prefilter DC 3035501 130 000 492 104 11 42 74 x 18 x 24 118 0 x 45 7 x 61 0 1 84 38 1 7 356 00 Homespri...

Page 45: ...6 00 White AR X Replacement Head EV3080 44 85 20 Dip Tube Assembly EV3080 40 15 40 Replacement Pressure Relief EV3071 20 23 00 Product Part Number List Price Tubing AllTubing available per foot 100 ft...

Page 46: ...gt Flakers 3500 lbs day IMI Cornelius Manitowoc Follett Ice O Matic Scotsman Replacement Cartridges EV9534 26 EC 210 Prefilter 1 ea EV9612 32 i 4000 2 4 ea Optional prefilter prolongs filter life in d...

Page 47: ...sizing recommendations are merely general guidelines For exact sizing by Manufacturer and model number please contact Everpure Technical Service servicespecialist pentair com or 800 942 1153 Micro Pur...

Page 48: ...Claris XL 12 Grains of Hardness ESO 7Twin ESO 7Triple Claris XXL or R O recommended Claris L Claris XL Claris XXL These sizing recommendations are merely general guidelines For exact sizing by Manufa...

Page 49: ...s 7500 gallons 2 gallon Medium WB 804 023 6 gallon Medium WB 804 037 6 gallon Max WB 804 037 Ambient Carbonator carbonated beverages only 1 Carbonator 2 Carbonators 3 Carbonators 4 Carbonators Coldrin...

Page 50: ...low water pressure can cause premature filter expiration and poor quality drinks For locations with low or inconsistent water pressure you should consider a SHURflo Water Boost System Ambient Carbonat...

Page 51: ...ric boiler systems 48 kW greater Water Requirements 12 0 grains gallon hardness System EV9797 22 KleenSteam IITwin Replacement Cartridges EV9618 11 2 ea 7CB5 Carbon EV9799 22 1 ea SS 10 ScaleStick Dir...

Page 52: ...w rate effective to 200 F Inhibits limescale build up reduces corrosion Simple effective Hydroblend technology Replacement Cartridges EV9799 22 HT 10 Cartridge 1 ea Usually lasts up to 6 months depend...

Page 53: ...EV9799 32 SS IMF 1 ea EV9437 10 Everpure High Flow CSR Quad MC2 System System EV9437 10 CSR Quad MC 2 Requirements Specifications Micro Pure II media with anti microbial protection inhibits potential...

Page 54: ...1 Single 0 5 1 9 1 0 3 8 1 67 6 3 2 5 9 5 2 Twin 1 0 3 8 2 0 7 6 3 34 12 6 5 0 19 0 3 Triple 1 5 5 7 3 0 11 4 5 01 18 9 7 5 28 5 4 Quad 2 0 7 6 4 0 15 1 6 68 25 2 10 0 38 0 Configured System Capacitie...

Page 55: ...dup You should consider post filtration any time your system is delivering water to more than one application Post filtration is highly recommended when you are running pieces of equipment that either...

Page 56: ...ation Plus Pre Filtration and Post Treatment Includes prefilter and scale reduction cartridge EV929402 High Flow CSR 10 PF Twin Manifold EV929403 High Flow CSR 10 PF Triple Manifold EV929404 High Flow...

Page 57: ...P 3G CL SA 12 C EV311239 153195 06 20 SMP 3G CL SA 8 C EV311238 153197 06 10 SMP 3G ST BL PP 12 C EV311256 153200 06 HOUSING FILTER 20 OPAQUE EV311255 154195 06 CAP BK HFPP W PR 3 4 BULK 18 C EV310108...

Page 58: ...BLACK W CVR EV312158 CH34342 TANK MINERAL 36 x 72 W BASE 6 FL EV311952 CH34343 TANK MINERAL 42 x 72 W BASE 6 FL EV312398 CH5665 DST KIT 14 16 TOP MOUNT EV311978 CH5666 DST KIT 18 COMP 21 FRP EV311979...

Page 59: ...Sub Micron Filtration 15 Gallon Storage Tank 115 Volt 8 EV997108 225 GPD RO with Sub Micron Filtration 30 Gallon Storage Tank 115 Volt 9 EV997109 225 GPD RO with Sub Micron Filtration 50 Gallon Storag...

Page 60: ...Storage Tank 115 Volt 52 EV997184 700 GPD RO with Booster Pump 15 Gallon Storage Tank 115 Volt 53 EV997185 700 GPD RO with Booster Pump 30 Gallon Storage Tank 115 Volt 54 EV997186 700 GPD RO with Boos...

Page 61: ...k 230 Volt 99 EV997263 575 GPD RO with 50 Gallon Storage Tank 230 Volt 100 EV997264 575 GPD RO with Booster Pump 15 Gallon Storage Tank 230 Volt 101 EV997265 575 GPD RO with Booster Pump 30 Gallon Sto...

Page 62: ...s costs of collection including without limitation reasonable attorneys fees 6 Delivery Shipments and Export Controls Delivery and Shipment Shipping date s proposed by Seller constitutes only an estim...

Page 63: ...s and engineering infor mation provided by Seller shall at all times be and remain vested in Seller 13 Governing Law Except where inconsistent with the express provisions of these Terms and Conditions...

Page 64: ...10 9320 1176 15 054 30 ED H 1 Scale Reduction 155248 43 P12 10 COR 10sIMF CFS4201MF AP420 9320 1150 4715 87 PFS10sIMF 101 260 15 054 20 ED L 1 CompetitiveCrossReferenceGuidefor20 StandardHousings Med...

Page 65: ...SYS DEMO 1 649 00 3024923 FILTER REPLACEMENT UF211 SS 180 00 42 3024924 FILTER REPLACEMENT UF211 180 00 42 3024925 FILTER REPLACEMENT UF211 QUAD 56 70 42 3030217 HOMESPRING UF211S SS 230V ROHS 7 356 0...

Page 66: ...ING BRACKET 62 20 EV306032 STANDARD HEAD ASSY 84 10 EV306107 PLSTC HD BODY QC W RINGS 30 90 EV306136 MALE CONNECTOR PLATED 47 80 EV306193 HEAD LC QC RINGLET 3 8NPT 26 80 EV306332 QL2 HEAD ASSY 65 60 E...

Page 67: ...2247 VALVE BALL 3 4 FNPT X 3 4FNPT 53 80 EV312248 VALVE BALL 3 4FNPT X 3 8BARB 53 80 EV312251 NIPPLE 1 2 X 3 8 PE 2 70 EV312295 ADAPTER 3 4 MNPT X 3 4 MNPT 4 80 EV312296 VALVE CHECK NEOPERL 11 50 EV31...

Page 68: ...4 20 10 EV910703 CARTRIDGE QCP TSGAC 12PK 48 60 10 EV910721 HEAD QCP SINGLE 1 4 JF 48PK 30 90 10 EV910722 HEAD QCP TWIN 1 4 JF 24PK 58 80 10 EV910723 HEAD QCP TRIPLE 1 4 JF 16PK 84 50 10 EV910811 CGT...

Page 69: ...V960700 7 DBG CART 1PK 148 00 EV960701 7DM CART 1PK 173 00 EV960702 7 NE CARTRIDGE 1PK 150 00 EV960703 7 OF CARTRIDGE 1PK 165 00 EV960704 7 SO CARTRIDGE 1PK 133 00 4 41 EV960705 7 TO CARTRIDGE 1PK 125...

Page 70: ...VAC US 4 699 00 31 EV998010 SOFTENER WS 30 115V 60HZ 1 973 00 28 EV998011 SOFTENER WS 45 115V 60HZ 2 016 00 28 EV998321 SOFTENER CES 2850M 68 2 988 00 28 EV998322 SOFTENER CES 2850M 102 3 407 00 28 EV...

Page 71: ...iminated with proper water conditioning HydroefficientTechnologies Everpure offers Hydroefficient technologies These are products that maximize water use and deliver you the highest quality product wh...

Page 72: ...eHub 21 609966 SINGAPORE TEL 65 6795 2213 FAX 65 6795 2219 EMAIL cseverpure pentair com Everpure SHURflo China 21F Cloud 9 Plaza No 1118 Shanghai 200052 CHINA TEL 86 21 3211 4588 FAX 86 21 3211 4580 E...

Reviews: