background image

20.0 508

5.0 127

3.1 80

16X .33

 THRU

8.4

17.8 452
16.6 422
15.4 391
14.2 361

4.2 107

Low TDS 

Outlet 

(Steamer)

Inlet 

(From Filter System)

Reduced TDS 

Outlet 

(Coffee)

ENVI-RO 

System

2SR-BW 

Conditioning 

Cartridge

MR-600 

RO Cartridge

RO Reject 

(3/8" John 

Guest) route 

to drain

figure 1.

 Wall mount bracket.

figure 2.

 ENVI-RO Assembly.

2

noteS:

 

Please read this manual prior to installing and operating the 

• 

system. 

Incoming water supplies that do not meet these requirements 

• 

may need additional pre-treatment prior to the system. System 

performance may be affected if requirements are not met, 

including system output production and cartridge change-out 

frequency. 

Consult with your local building inspector for approval and 

• 

required permits to install this system. Additional equipment, such 

as back-flow prevention devices, seismic restraint equipment, air 

gaps, etc., may be required. Completed installation must meet all 

local and national codes.

Do not connect the ENVI-RO™ system after any water filtration 

system, unless specifically provided or specified for use with the 

ENVI-RO™ system. 

unPackIng and InSPectIon

The ENVI-RO™ includes all the necessary fittings for installation. 

Lengths of 3/8" tubing have been provided for connecting to the 

wastewater/drain connection. Supply lines and distribution piping/

tubing are not included. 
The ENVI-RO™ system is packaged as a complete unit in one carton. 

At a minimum, you should have the following:

Plate mounted processor assembly including:

1. 

Dual-head Pump 

• 

Cartridge Heads 

• 

Controller & Power Supply

• 

Storage Tank 

• 
Wall Mount Bracket

2. 

MR-600 RO cartridge 

3. 

2SR-BW Cartridge

4. 

Parts Kit

5. 
Inspect the carton for damage. Report any damage to freight carrier 

immediately and retain all packaging materials. Carefully unpack and 

inspect each item. 

SyStem aSSembly

Locate the system in an area that is convenient to the inlet water 

supply and drain facilities, with access for routing the product water 

tubing/piping to the equipment. Install in a dry location, away from 

all forms of corrosive and/or flammable materials. Consider ease 

of access for servicing when selecting a location. Evaluate the 

mounting surface for its ability to properly support the weight of the 

processor when in operation (Approximately 90 pounds).

WARNING

  Do not use screws smaller than #12 for mounting the 

processor.

WARNING

  Mounting surface may require reinforcement to 

support processor safely. Hollow walls, drywall and 

other non-structural surfaces are not suitable unless 

reinforced.

Processor assembly mounting

The ENVI-RO system has been provided with a wall mount 

1. 

bracket to allow greater installation flexibility and ease of 

processor placement. If the wall mount bracket is not suitable for 

this specific application, the processor backplate has 4 mounting 

holes (2 keyhole slots, 2 standard) on 16" centers for securing it 

directly to a vertical surface. 
Refer to 

2. 

figure 7

 (page 13) for dimensional information. Use 

this as your guide to determine the wall mount bracket and/or 

processor location. If NOT installing the wall mount bracket go 

to step 5. 

continued on the next page  . . . 

Floor Drain

Maintain air-gap per local and national codes

Position top line of mounting holes 1-9/16” above 

the top edge of backplate

Summary of Contents for ENVI-RO

Page 1: ...increases the inlet pressure to maintain consistent permeate production plus eliminates back pressure on the permeate output This innovative approach to both boosting and eliminating back pressure al...

Page 2: ...ler Power Supply Storage Tank Wall Mount Bracket 2 MR 600 RO cartridge 3 2SR BW Cartridge 4 Parts Kit 5 Inspect the carton for damage Report any damage to freight carrier immediately and retain all pa...

Page 3: ...ectionable taste Plastic pipe or reinforced tubing are generally very good choices for RO water distribution materials The size of the product water tubing piping should be 3 8 ID minimum Distances of...

Page 4: ...alue in seconds is entered for this setting Range is 0 995 seconds in 5 second increments Use the keys to adjust this value Press Enter to save value and go to next screen Flush Int X2 This parameter...

Page 5: ...o your TDS measurement Read across that row to determine maximum recovery permeate to reject ratio and permeate reject volumes Using 2 32 oz or 1 000 ml graduated containers apply power 2 to the syste...

Page 6: ...1 321 67 9 679 751 1000 30 0 1 to 2 33 30 0 300 70 0 700 Table 2 Capillary Tube and Flush Time Selector Reject Volume per Minute Capillary Tube Flush Time in Seconds Ounces Milliliters 1 2 0 0 6 1 0 1...

Page 7: ...odor is detected from 8 the water exiting the storage tank or connected equipment Placing ENVI RO Into Service Once the cartridges have been activated the storage tank and distribution piping sanitiz...

Page 8: ...pm Dependant on Pressure volume in storage line sizes Volume Gallons Dependant on Pressure volume in storage Pressure typical 60 100 psi 4 1 6 9 bar Salt Rejection 90 minimum Recovery Varies based on...

Page 9: ...9 maintenance section Performance Log Test Date Outlet Flow ml min Drain Flow ml min Inlet Pressure Temp psi F Inlet TDS ppm STEAMER Outlet TDS ppm COFFEE Outlet TDS ppm Reduction NOTES...

Page 10: ...capacity if applicable c Low quality RO water 3 Refer to problem 1 a Refer to problem 1 a RO cartridge failure b Replace RO cartridge b Low water pressure at water 4 using equipment Tubing piping run...

Page 11: ...13 EV312827 RESTRICTOR BLUE 735 ml min 13 EV312828 RESTRICTOR WHITE 1052 ml min 13 EV312829 RESTRICTOR GREY 1577 ml min 13 EV312830 RESTRICTOR RED 125 ml min 13 EV312831 RESTRICTOR BROWN 189 ml min 1...

Page 12: ...instructions on the MR cartridge label Place a bucket under the cartridge to catch any excess water that may spill from the head Remove the old cartridge by turning the cartridge to the left until it...

Page 13: ...13 13 6 346 23 583 406 16 32 Side View Front View Top View 813 Figure 7 Dimensional Drawing...

Page 14: ...14 Figure 8 General Installation Arrangement...

Page 15: ...15 NOTES...

Page 16: ...00 942 1153 www everpure com Printed in U S A EV3128 25 Rev A SE08 For sales replacement components and service contact your Everpure dealer or Everpure LLC 1040 Muirfield Drive Hanover Park Illinois...

Reviews: