8.3.6.7 Door ajar alarm activation delay (touch-button (4)
Fig.16)
To access to the DELAY OF ACTIVATION OF DOOR AJAR ALARM, press the
touch-button (4)
while the display shows the second
page of the setting menu
(Fig.16).
- press the
touch-button (4)-
and
(7)+
to set the desired value (expressed In seconds, max. 600) that has to pass from the open-
ing of the door till its signalling on the display and through the buzzer
- press the
ENTER touch-button (12)
to confirm the new setting and the
ESC touch-button (11)
to return back to the previous
menu or
HOME touch-button (10)
to return back to the main screen-shot
8.3.6.8 Codes setting (touch-button (5)
Fig.16)
From this menu is possible to customize the 2 appliance access codes. The
ON/OFF code,
which is required every time that it is
needed to switch the appliance ON or OFF
(factory code 0050)
. The
Keyboard blocking code
, which has to be entered every time
that the appliance has been unused for 5 minutes
(factory code 0010).
To access to the screen-shot ACCESS CODE SETTING
(Fig.20)
, press the
touch-button (5)
while the display shows the second
page of the setting menu
(Fig.16).
To set a new ON/OFF code, proceed as follow:
- press the
touch-button (4)
to access to the screen-shot ON/OFF CODE
- using the touch-buttons
(3)
ç
and
(6)
è
highlight the position in the code that should be modified
- using the touch-buttons
(4)-
and
(7)+
to set the desired value
- press the
ENTER touch-button (12)
to confirm the new setting and the
ESC touch-button (11)
to return back to the previous menu
To set a new Keyboard blocking code, proceed as follow:
- press the
touch-button (4)
to access to the screen-shot KEYBOARD BLOCKING CODE
- using the
touch-buttons (3)
ç
and
(6)
è
highlight the position in the code that should be modified
- using the
touch-buttons (4)-
and
(7)+
to set the desired value
- press the
ENTER touch-button (12)
to confirm the new setting and the
ESC touch-button (11)
to return back to the previous menu
NB:
Setting the value "9999" function will be disabled.
8.3.6.9 Calibration (touch-button (6)
Fig.16)
From this menu is possible to manually calibrate 2 sensors of the appliance. The Chamber sensor is the one acquiring the tempera-
ture into the appliance, while the Product simulation sensor (optionally available) simulate the temperature of the products stored into
the appliance with a ballasting of 250 ml of water (or anti-freezing liquid). Through this menu is possible to adjust the reading of the
sensors according to reading of external comparison thermometers, data loggers, thermocouples or personal wishes. To access to the
CALIBRATION SETTING
(Fig.21)
, press the
touch-button (6)
while the display shows the second page of the setting menu
(Fig.16)
To set a new calibration for the Chamber sensor, proceed as follow:
- press the
touch-button (4)
to access to the screen-shot CALIBRATION CHAMBER SENSOR
- press the
touch-button (4)-
and
(7)+ to increase
(max + 10°C) or lower (min -10°C) the calibration value highlited
- press the
ENTER touch-button (12)
to confirm the new setting and the
ESC touch-button (11)
to return back to the previous
menu or
HOME touch-button (10)
to return back to the main screen-shot
To set a new calibration for the Product simulation sensor (optionally available), proceed as follow:
- press the
touch-button (4)
to access to the screen-shot CALIBRATION PRODUCT SENSOR
- press the
touch-button (4)-
and
(7)+
to increase
(max +10°C) or lower (min -10°C) the calibration value highlited
- press the
ENTER touch-button (12)
to confirm the new setting and the
ESC touch-button (11)
to return back to the previous
menu or
HOME touch-button (10)
to return back to the main screen-shot
Keyboard
blocking code
ON/OFF code
ACCESS CODE
SETTING
Fig.20
(4)
(7)
Fig.21
(4)
(7)
Product
simulation
sensor
Chamber sensor
CALIBRATION
SETTING