52
106
Pbu
2
Enables functions or keyboard and buzzer configuration.
0 = no; 1 = solo allarme no tasti; 2 = allarme e
tasti
N.
PAR.
DEF.
SAFETIES
MIN... MAX.
107
PAS
-19
Parameter password
-99... 999
108
PS1
1
Service level 1 password
-99... 999
109
PA1
426
Evlink/Evconnect user password
-99... 999
110
PS2
824
Evlink/Evconnect service password
-99... 999
N.
PAR.
DEF.
CLOCK
MIN... MAX.
111
Hr0
0/1
Enables clock for models without integrated rtc.
0 = no 1 = si
N.
PAR.
DEF.
DATA LOGGER
MIN... MAX.
112
BLE
1
1= EVLINK presence. Leave LA Lb and LP at default. Set
to 0 to enable Modbus communication with EVIF22/23TSX
modules.
0 = no (Modbus) 1 = si (EVLINK)
113
rE0
15
Recording interval
0..240 min
114
rE1
4
Value to be recorded
0=nessuna; 1=sonda 1; 2=sonda 2; 3= Sonda 3;
4=sonda 1 e sonda 2; 5= tutte le sonde
N.
PAR
DEF
REAL-TIME DEFROSTING
MIN… MAX
115
Hd1
- - -
1° Defrosting Time
0..24 h
116
Hd2
- - -
2° Defrosting Time
0..24 h
117
Hd3
- - -
3° Defrosting Time
0..24 h
118
Hd4
- - -
4° Defrosting Time
0..24 h
119
Hd5
- - -
5° Defrosting Time
0..24 h
120
Hd6
- - -
6° Defrosting Time
0..24 h
N.
PAR.
DEF.
MODBUS RS485
MIN... MAX.
121
LA
247
MODBUS address. Set BLE=0 for monitoring (deactivates
datalogger and BLE)
1... 247
122
Lb
3
MODBUS Baud Rate
0 = 2400; 1 = 4800 2 = 9600; 3 = 19200
123
LP
2
Modbus Parity
0= None 1= Odd 2= Even
N.
PAR.
DEF.
ENERGY SAVING (if r5 = 0)
MIN... MAX.
124
HE2
0
Manual Energy Saving duration
0..990 min
125
H01
0
Daily Start time for Temperature Energy saving
0..23h
126
H02
0
Daily Temperature Energy Saving duration
0..24h