33
ENGLISH
Fig.5
- position the grille holding guide fails in the holes of the racks (Fig. 6 )
Fig.6
- insert the grilles for food in the special guides
- insert the condensate water drain pan into the special guide rails already fixed under the refrigerated
cabinet if provided.
14.2 REM cabinets ( Fig. 7 )
Fig.7
- position the refrigerated cabinet as described above (Fig. 5)
- arrange the two pipes coming out of the refrigerated cabinet (liquid line ø 6 mm, suction ø 10 mm
TNBV - ø 12 mm BTV) to connect them to the respective pipes
- connect the pipes of the condensing unit to the pipes of the refrigerated cabinet
- create a vacuum and then carry out the loading of the coolant
- make the electrical connection of the refrigerated cabinet to the condensing unit
- perform a functional test to verify the correct gas charge.