10
STAGIONATORE
Section
7: DIAGNOSTIC
In case these problems arise, please follow the instructions stated in the following chart:
PROBLEM
POSSIBLE CAUSE
SOLUTION
Appliance does not switch on
power failure
check plug, socket, fuses, electrical line
other
contact technical service
Refrigeration unit does not start
set temperature has been reached
set new temperature
defrosting cycle is in progress
wait for cycle to end, then switch off and on again
control panel breakdown
contact technical service
other
contact technical service
Refrigeration unit runs constantly,
but does not reach set temperature
room is too hot
provide better ventilation
condenser is dirty
clean the condenser
refrigerant needs to be recharged
contact technical service
condensing fan is not running
contact technical service
inefficient door seals
check seals / how goods are placed inside the
cabinet
evaporator is coated with ide
manual defrosting
other
contact technical service
Refrigeration unit dos not stop at
set temperature
control panel breakdown
contact technical service
temperature probe breakdown
contact technical service
Ice block on the evaporator
improper use
see section 3.4
defrost resistance breakdown
contact technical service
defrost probe breakdown
contact technical service
Water or ice deposits in the drip tray
obstructed drain
clean the drain and the drain outlet
refrigerated counter is not levelled
check levelling