Mains water supply

As  mains  pressure  commonly  exceeds  500  –  550  kPa,  a  pressure  limiting 

valve should be installed set to 500 kPa maximum. Note: In some States a 

cold water expansion valve must be installed by regulation. This valve must 

be set at 700 kPa maximum. 
As  shown  in  figure  1  and  2,  an  approved  isolating  valve,  line  strainer  and 

union are recommended between the cold water supply main and the cold 

water inlet of the Everlast™ Series 2000 water heater. Plumbing compliance 

(safety) regulations require the installation of the supplied Non Return Valve 

to ensure that the appliance does not empty during normal use or interrupted 

water supply.
The Everlast™  Series 2000 water heater is designed to ensure total drainage 

for flushing if required. It is recommended that a drain cock be installed on 

the cold water inlet pipe adjacent to the heater to facilitate flushing annually in 

poor water quality areas.
Hot water connection should be as shown in figure 1 and 2. It is recommended 

that hot water outlet pipes are fully insulated withweatherproof insulation, and 

that the hot water outlet pipe is slightly curved or stepped down adjacent to the 

water heater outlet to provide a positive heat trap and avoid thermal siphoning 

from the heater.

EVERLAST MANUAL 16pp.indd   5

9/07/10   11:02 AM

NON STANDARD INSTALLATIONS

The installation diagrams on the following pages refer to standard domestic 

connections / installs.

For Solar and Commercial applications please refer to the relative system 

suppliers connection / installation instructions.

Summary of Contents for series 2000

Page 1: ...EVERLAST MANUAL 15 8 2008 indd 1 20 8 08 10 35 05 AM EVERLAST MANUAL 16pp indd 1 9 07 10 11 02 AM...

Page 2: ...ncluding Marine Grade stainless steel cylinder Control of thermal stratification Dual Positive Domed Cylinder resulting in optimum location of element s water supply and delivery and flushing through...

Page 3: ...osphere and suitably located to not become blocked Should a continuous discharge occur we recommend that you consult your licensed plumber as this may indicate a defective P T valve defective thermost...

Page 4: ...ustible Material It is recommended to not place combustible material on or adjacent to the water heater Internal Installation Safe Tray For internal indoor installations a safe tray is recommended in...

Page 5: ...00 water heater is designed to ensure total drainage for flushing if required It is recommended that a drain cock be installed on the cold water inlet pipe adjacent to the heater to facilitate flushin...

Page 6: ...a and 99 C The Expansion Control Valve if required by some Authorities is set to 700 kPa max AS MAINS pressure COMMONLY exceeds 500 kPa fit A Pressure Limiting Valve set to 500 kPa INSTALLATION DIAGRA...

Page 7: ...RMAL THERMOSTAT MAXIMUM THERRMOSTAT THERMAL CUT OUT THERMOSTATS MODEL NUMBER SETTING SETTING NON SOLAR APPLICATIONS Top Thermostat ST2207233 Fixed at 60 C Fixed at 60 C 88 C Bottom Thermostat ST120113...

Page 8: ...the Circuit Continuity Test across the element which should indicate an element resistance of approx 11 13 Ohms ALWAYS carry out circuit continuity tests with no circuit load as the element resistanc...

Page 9: ...rmostat 5 will be OPEN CIRCUIT with CLOSED CIRCUIT between 1 and 4 until bottom element has heated water above 60 C Above 60 C 1 2 is now CLOSED CIRCUIT AND 1 4 is now OPEN CIRCUIT Therefore Wiring Te...

Page 10: ...cturer The thermostat model numbers are noted on the Wiring Plans Figures 3 4 DANGER The operation of the over temperature safety cut out indicates a possibly dangerous situation Do not reset the ther...

Page 11: ...aps may be opened fully and the pressure and temperature relief valve closed with care The cold water inlet stop valve is now opened fully and the water heater may be filled with cold water and flushe...

Page 12: ...he following warranty exclusions may cause the system warranty to become void This may incur a service charge and cost for parts should they be necessary 1 Where service is required to reconnect the w...

Page 13: ...ect of the product which the purchaser has under the Trade Practices Act Commonwealth 1975 and similar State or Territory Laws Warranty Cover Single Domestic Single Multi Application Commercial Applic...

Page 14: ...________________________________________________________________ Town Suburb__________________________State____________Postcode ___________ Electrician____________________________________Licence No _...

Page 15: ...______________ Installed by Plumber____________________________________ Licence No _______________ Address _____________________________________________________________ Town Suburb____________________...

Page 16: ...Printed May 2012 Product Code number 44953 EVERLAST MANUAL 16pp indd 16 9 07 10 11 02 AM...

Reviews: