Information regarding your EVERLAST Series 2000, Electric 

Water Heater.

Congratulations for choosing an Everlast™ Water Heater. The unit has been 

manufactured to Australian Standards AS 1056.1 and AS/NZS 60335.2.21, 

and incorporates a STAINLESS STEEL CYLINDER produced from marine 

grade stainless steel and which is  covered by a 10 year warranty as per the 

enclosed warranty conditions. The stainless steel cylinder gives longevity 

of service and also less maintenance because there is no sacrificial anode. 

The Everlast™ Series 2000 Electric Water Heater will provide continuous hot 

water for many years to come. 

1        Features of your Everlast™ Water Heater

The Everlast™ Series 2000 is an electric storage water heater that  

can be heated using standard or “off peak” electricity. Your electricity supply 

authority can provide you with information in relation to the “off peak” tariff 

applicable to your particular location.
The Everlast™ Series 2000 incorporates the latest aspects of design and 

material selection including :

  Marine Grade stainless steel cylinder,

   Control of thermal stratification, 

   Dual Positive Domed Cylinder resulting in optimum location of  

 

  element(s), water supply and delivery and flushing-through of  

 

  suspended solids.

   Highest level of insulation due to the use of a polymeric external    

  casing combined with thick polyurethane insulation.
The Everlast™ Series 2000 heats potable water in the storage  

cylinder by one or more immersion elements (depending upon model).
A thermostatically controlled electric element in the bottom of the  

cylinder can be connected to normal or “Off Peak” power supply. A  

second optional booster in the top half of the cylinder ( in twin element  

models ) is used to add additional hot water as required. The heated water 

rises up the cylinder by natural convection to the top where it is ready for use. 

As hot water leaves the storage cylinder, it is replaced by cold water, which 

enters at the bottom of the cylinder.

Everlast™ recommends flushing the water heater at regular intervals as 

advised by your licensed plumber, and to assist this operation, the cold water 

inlet has a large opening for flushing any built up solids that have escaped 

the line strainer.

EVERLAST MANUAL 16pp.indd   2

9/07/10   11:02 AM

Summary of Contents for series 2000

Page 1: ...EVERLAST MANUAL 15 8 2008 indd 1 20 8 08 10 35 05 AM EVERLAST MANUAL 16pp indd 1 9 07 10 11 02 AM...

Page 2: ...ncluding Marine Grade stainless steel cylinder Control of thermal stratification Dual Positive Domed Cylinder resulting in optimum location of element s water supply and delivery and flushing through...

Page 3: ...osphere and suitably located to not become blocked Should a continuous discharge occur we recommend that you consult your licensed plumber as this may indicate a defective P T valve defective thermost...

Page 4: ...ustible Material It is recommended to not place combustible material on or adjacent to the water heater Internal Installation Safe Tray For internal indoor installations a safe tray is recommended in...

Page 5: ...00 water heater is designed to ensure total drainage for flushing if required It is recommended that a drain cock be installed on the cold water inlet pipe adjacent to the heater to facilitate flushin...

Page 6: ...a and 99 C The Expansion Control Valve if required by some Authorities is set to 700 kPa max AS MAINS pressure COMMONLY exceeds 500 kPa fit A Pressure Limiting Valve set to 500 kPa INSTALLATION DIAGRA...

Page 7: ...RMAL THERMOSTAT MAXIMUM THERRMOSTAT THERMAL CUT OUT THERMOSTATS MODEL NUMBER SETTING SETTING NON SOLAR APPLICATIONS Top Thermostat ST2207233 Fixed at 60 C Fixed at 60 C 88 C Bottom Thermostat ST120113...

Page 8: ...the Circuit Continuity Test across the element which should indicate an element resistance of approx 11 13 Ohms ALWAYS carry out circuit continuity tests with no circuit load as the element resistanc...

Page 9: ...rmostat 5 will be OPEN CIRCUIT with CLOSED CIRCUIT between 1 and 4 until bottom element has heated water above 60 C Above 60 C 1 2 is now CLOSED CIRCUIT AND 1 4 is now OPEN CIRCUIT Therefore Wiring Te...

Page 10: ...cturer The thermostat model numbers are noted on the Wiring Plans Figures 3 4 DANGER The operation of the over temperature safety cut out indicates a possibly dangerous situation Do not reset the ther...

Page 11: ...aps may be opened fully and the pressure and temperature relief valve closed with care The cold water inlet stop valve is now opened fully and the water heater may be filled with cold water and flushe...

Page 12: ...he following warranty exclusions may cause the system warranty to become void This may incur a service charge and cost for parts should they be necessary 1 Where service is required to reconnect the w...

Page 13: ...ect of the product which the purchaser has under the Trade Practices Act Commonwealth 1975 and similar State or Territory Laws Warranty Cover Single Domestic Single Multi Application Commercial Applic...

Page 14: ...________________________________________________________________ Town Suburb__________________________State____________Postcode ___________ Electrician____________________________________Licence No _...

Page 15: ...______________ Installed by Plumber____________________________________ Licence No _______________ Address _____________________________________________________________ Town Suburb____________________...

Page 16: ...Printed May 2012 Product Code number 44953 EVERLAST MANUAL 16pp indd 16 9 07 10 11 02 AM...

Reviews: