LIGHTING THE WATER HEATER
FOR YOUR SAFETY READ BEFORE LIGHTING
Warning:
This
gas water heater is designed to operate reliably and safely as long as the lighting procedure
is followed
exactly
.
Make sure the water heater is filled with water and the water supply is on, otherwise serious damage to the
vitreous enamel cylinder lining and plastic components may occur.
The installer must purge the gas line up to the gas control (refer to
on page 32), check all gas
connections for leaks, gas supply pressure, test point pressure (refer rating label).
Notes
•
625275 indoor model - remove the transport clip from the flue damper
housing.
•
A viewing window is provided to check burner operation on the water
heater.
LIGHTING PROCEDURE
The water heater incorporates an automatic ignition system.
1. Switch on the electrical supply at the isolating switch to the water heater.
2. When the controlling thermostat registers heating is required, the hot surface igniter rod warms up for
20 seconds. The burner will automatically ignite.
3. If burner ignition is unsuccessful, a second and third re-ignition attempt will occur after a five (5) minute
delay between each try. This delay is to allow for any build-up of unburnt gas to escape.
4. If the third attempt is also unsuccessful, the system enters the re-ignition attempt lockout mode. To reset
the water heater, press the illuminated red reset button. The button is located on the left hand side of the
front cover and above the gas inlet. If the water heater fails to light, phone Rheem Service or their nearest
Accredited Service Agent to arrange for an inspection.
TEST THE WATER HEATER AFTER INSTALLATION
•
The operation of the water heater must be thoroughly checked by the installer.
•
The burner flame must light smoothly and quickly from the hot surface igniter and must go out quietly and
completely.
•
The burner flame must be stable, although slight lifting at the front edge of the burner is acceptable when
the burner is cold.
•
The burner flame should be blue, with a clearly defined inner cone - luminous yello
w or “floating” flames
are not acceptable.
•
Check the test point pressure and compare with the rating label. Adjust if necessary.
•
If unable to get the water heater working properly, contact Rheem Service or their nearest Accredited
Service Agent to arrange for an inspection.
•
When satisfied everything is working properly instruct the user in the correct method of operation.
transport clip