![EverFocus PARAGON 264x4-16 Instruction Manual Download Page 18](http://html1.mh-extra.com/html/everfocus/paragon-264x4-16/paragon-264x4-16_instruction-manual_2443286018.webp)
12
The Control Input Contact CTRL IN is defined in I/O Control menu (
chapter
Fehler! Verweisquelle
konnte nicht gefunden werden.
) for following possible functions:
1. Playback:
Playback is active as long the contact is closed. This function is helpful in
combination with the "Quickplay" function (
chapter 5.4.3)
CTRL IN
GND
CTRL IN
GND
Idle state
Playback
2. Record:
The input switches to Record (or Record Standby) as long the contact is closed.
CTRL IN
GND
CTRL IN
GND
Idle state
Record / Record Standby
3. Armed / Disarmed:
If the contact is closed, the DVR will switch off alarm (alarm contact and motion
alarm) operation. System alarm events are always active.
CTRL IN
GND
CTRL IN
GND
DVR armed
DVR disarmed
2.3.3
Alarm Output Relay
The relay outputs provide either Normally Open or Normally Closed dry contacts.
Output relay in idle state