EverFocus ES0802-41 User Manual Download Page 28

                                             

  PoE Switch 

23 

 

Remote access and monitor the attached PD (Powered Device) status by using 
Enable/Disable function. 

 

PoE Enabled: POE of the port is able to supply power to the attached PD (Powered 
Device) 

 

PD Class: Detect the class of PD 

 

Delivering Power (W):

 

Output power 

 

Current (mA): The status of the port current 

 

Voltage (V): The status of the port current 

 

Power Budget: Total PoE power has been used 
 

 

Figure 1-12-1 

Storm Control 

Broadcast storms may occur when a device on your network is malfunctioning, or if 
application programs are not well designed or properly configured. If there is too 
much broadcast traffic on your network, performance can be severely degraded or 
everything can come to complete halt. 

You can protect your network from broadcast storms by setting a threshold for 
broadcast traffic for each port. Any broadcast packets exceeding the specified 
threshold will then be dropped. 

Storm Control Configuration 

There are three type of traffic which can be rate limited, including broadcast 
multicast frame and Flooded Uncast Rate. 

Summary of Contents for ES0802-41

Page 1: ...802 41 8 port 10 100 1000M PoE Web Smart Gigabit Ethernet Switch User s Manual Copyright EverFocus Electronics Corp Release Date September 2013 Notice This content is subject to be changed without not...

Page 2: ...erfocus Electronics Corporation Release Date September 2013 QuickTime is a registered trademark of the Apple Computer Inc Windows is a registered trademark of the Microsoft Corporation Linksys is a re...

Page 3: ...will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is...

Page 4: ...al Dimensions Weight 4 Front Panel 4 LED Indicators 4 Rear Panel 5 Hardware Installation 5 3 Software Description 6 3 1 Configuration 7 System 7 Ports 9 VLAN 10 Aggregation 13 LACP 13 RSTP 14 IGMP Sno...

Page 5: ...Ping 30 3 3 Maintenance 32 Warm Restart 32 Factory Default 32 Software upload 33 Configuration File Transfer 33 Logout 33 3 4 Reset button for the factory default setting 34...

Page 6: ...ps It can be installed where space is limited moreover it provides smooth network migration and is easy to upgrade the network capacity In addition the switch features comprehensive and useful functio...

Page 7: ...ications Standard IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX IEEE 802 3ab 1000BaseT IEEE 802 3af PoE IEEE 802 3at PoE IEEE 802 3z 1000BaseSX LX IEEE 802 3x Full duplex Flow Control IEEE 802 3ad Link Agg...

Page 8: ...Dimensions Weight 266 160 44 mm L W H 1 6kg 1 5 Performance MAC Address Multicast group 8K Buffer Memory 176 KB Jumbo Frames 9 6K Transmission Method Store and Forward 1 6 Package Contents Before you...

Page 9: ...SFP open slot The LED Indicators are also located on the front panel LED Indicators The LED Indicators present real time information of systematic operation status The following table provides descri...

Page 10: ...e switch on a large flat space with a power socket close by The flat space should be clean smooth level and sturdy Make sure there is enough clearance around the switch to allow attachment of cables p...

Page 11: ...he description to understand the procedure At the first open the web browser and go to 192 168 2 1 site then the user will see the login screen Just clicks the Apply then the login process is complete...

Page 12: ...PoE Switch 7 Figure 1 2 3 1 Configuration System System Configuration This page shows system configuration information User can configure lots of information as Fig 1 3...

Page 13: ...ardware version DHCP Enabled Click the box to enable DHCP Fallback IP address Manually assign the IP address that the network is using The default IP is 192 168 2 1 Fallback Subnet Mask Assign the sub...

Page 14: ...retrieve MIB objects SNMP Trap Community Community string sent with the notification operation Ports Port Security ensures access to a switch port based on MAC address limits the total number of devic...

Page 15: ...hich would allow you to isolate network traffic so only the members of the same VLAN will receive traffic from the ones of the same VLAN Basically creating a VLAN from a switch is logically equivalent...

Page 16: ...Lists all the current VLAN groups created for this system Up to 16 VLAN groups can be defined VLAN 1 is the default untagged VLAN Figure 1 5 1 VLAN Setup The switch supports up to 16 VLANs based on 80...

Page 17: ...Filtering Enabled If enabled incoming frames for VLANs which do not include this ingress port in their member set will be discarded Default Disabled Packet Type Sets the interface to accept all frame...

Page 18: ...y the link does not have an inherent total bandwidth equal to the sum of its component physical links Traffic in a trunk is distributed across an individual link within the trunk in a deterministic me...

Page 19: ...er recovery from failed links enhancing overall network stability and reliability RSTP System Configuration System Priority This parameter configures the spanning tree priority globally for this switc...

Page 20: ...igured trunk group Enabled Click on the tick box to enable disable the RSTP protocol for the port Edge Expect the port to be an edge port linking to an end station or a link to another STP device Path...

Page 21: ...PoE Switch 16 Figure 1 8 2 Figure 1 8 3 Figure 1 8 4...

Page 22: ...oding of IP multicast traffic and limits bandwidth intensive video traffic to only the subscribers IGMP Configuration IGMP Enabled When enabled the switch will monitor network traffic to determine whi...

Page 23: ...ion system Mirroring Configuration Port to Mirror to The port that will duplicate or mirror the traffic on the source port Only incoming packets can be mirrored Packets will be dropped when the availa...

Page 24: ...equential order transmitting all traffic in the higher priority queues before servicing lower priority queues WRR Weighted Round Robin shares bandwidth at the egress ports by using scheduling weights...

Page 25: ...1p field in the VLAN tag This field is three bits long representing the values 0 7 When the QoS Mode is set to 802 1p the 802 1p Configuration table appears allowing you to map each of the eight 802 1...

Page 26: ...hin an IP TCP or UDP header The six bits allow the DSCP field to take any value in the range 0 63 When QoS Mode is set to DSCP the DSCP Configuration table is displayed allowing you to map each of the...

Page 27: ...whole new application aspect for networking products A series of PoE product is powering for wide range of devices especially useful for VoIP phones wireless LAN access points and IP cameras It is dep...

Page 28: ...l Broadcast storms may occur when a device on your network is malfunctioning or if application programs are not well designed or properly configured If there is too much broadcast traffic on your netw...

Page 29: ...threshold is exceeded packets are dropped irrespective of the flow control settings Web Click PORTS Storm Control This page enables you to set the broadcast storm control parameters for every port on...

Page 30: ...PoE Switch 25 Figure 2 1 Detailed Statics Figure 2 2 LACP Status LACP Aggregation Overview Figure 2 3 1...

Page 31: ...ion message Max Age The maximum time in seconds a device can wait without receiving a configuration message before attempting to reconfigure All device ports except for designated ports should receive...

Page 32: ...of a static trunk Path Cost The cost for a packet to travel from this port to the root in the current Spanning Tree configuration The slower the media the higher the cost Edge Port Shows if this port...

Page 33: ...ed v2 Report packets v3 Reports Show the number of received v2 Report packets v3 Leave Show the number of v3 leave packets received Figure 2 5 VeriPHY VeriPHY Cable Diagnostics User can perform cable...

Page 34: ...PoE Switch 29 Figure 2 6 1 Figure 2 6 2 Figure 2 6 3...

Page 35: ...nother site on the network can be reached The following are some results of the ping command Normal response The normal response occurs in one to ten seconds depending on network traffic Destination d...

Page 36: ...PoE Switch 31 Figure 2 7 1 Figure 2 7 2...

Page 37: ...en the power lights stop blinking Figure3 1 Factory Default This function is to force the switch back to the original factory settings To reset the switch select Reset to Factory Defaults from the dro...

Page 38: ...e the switch s current configuration or restore a previously saved configuration back to the device Configuration files can be saved to any location on the web management station Upload the configurat...

Page 39: ...ps to reset the Web Smart Switch back to the original default Step 1 Turn on the Web Smart Switch Step 2 Press and hold the reset button continuously for 5 seconds and release the reset button Step 3...

Page 40: ...3 5625 8189 www everfocus co jp info everfocus co jp EverFocus Europe UK Unit 12 Spitfire Business Park Hawker Road Croydon Surrey CR0 4WD UK TEL 44 20 8649 9757 44 845 430 9999 FAX 44 20 8649 9907 ww...