54
HD Temperature:
Figure 5-12 Alarm & Event Menu – Event - HD Temperature
Log:
Check box to record events in the log.
Buzzer:
Check box to enable buzzer when hard drive’s temperature is over the “Temp. Warning Limit”.
Email Notify:
Check box to enable email notification when temperature is over the “Temp. Warning Limit”.
Network Alarm:
Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Stop Recording:
Check box to stop recording when HD’s temperature is over the “Temp. Warning Limit”.
Temp. Warning Limit:
Sets the trigger temperature for all other active settings in HD Temperature.
Choose from 55
°
C /131
°
F~85
°
C /185
°
F.
Alarm Output:
This will transmit a signal through one of the alarm outputs. It can be set to either “
NONE
”
(not active) or, “
1
””.
Output Type:
Output action is locked to
Transparent.
Summary of Contents for ELR-4
Page 1: ...Instruction Manual E EL LR R 4 4 E EL LR R 8 8 ...
Page 14: ...7 11 LAN RJ 45 network connection ...
Page 36: ...29 7 Zoom in 11 Zoom out ...
Page 53: ...46 ...
Page 100: ...93 ...
Page 101: ...94 ...