EDR910_1610_ma_en_rev1
00
- 46 -
3.11 WARNING MENU
The EDR provides warning functions allowing signalling upon operation failure. Define the
alarm reactions in the WARNING menu.
3.11.1 FAN FAILURE
Both fans provide failure detection. Define the alarm reactions upon fan failure in this
menu item:
(1) BUZZER:
By selection “ENABLE”, the buzzer is activated upon fan
failure.
(2) ALARM OUTPUT:
Output relay activation.
1
:
Output relay
NONE:
No relay reaction upon alarm.
(3) ALARM DURATION: PERMANENT
This value cannot be changed, alarm is
automatically
switched off after problem has
been solved (fan replacement).
(4) NETWORK ALARM: YES:
Network alarm activated (for settings refer
to NETWORK menu)
Network alarm reception requires optional
PowerCon software.
NO:
No network alarm transmission
(5) EMAIL:
YES:
Alarm email transmission (for settings refer
to NETWORK menu).
NO:
No email alarm transmission.
WARNING SETUP MENU
FAN
FAULT
BUZZER
ENABLE
HDD TEMP.
ALARM OUTPUT
1
NO HDD
ALARM DURATION
PERMANENT
HDD FULL
NETWORK ALARM
NO
NO