![EverFocus EDR-1610A Installation & Operation Manual Download Page 45](http://html1.mh-extra.com/html/everfocus/edr-1610a/edr-1610a_installation-and-operation-manual_2443161045.webp)
EDR910_1610_ma_en_rev1
00
- 45 -
3.10 RS232/RS485 MENU
Define the settings for DVR remote control through serial interface in the
RS232/RS485
menu. Pin assignment and remote control protocol are described in appendix B and C.
(1) RS232 BAUD RATE:
RS-232 interface transmission speed. 1200, 2400, 4800,
9600, 19200 and 3840 baud can be selected.
Default setting: 9600 baud
(2) RS232 STOP BIT:
Number of stop bits: 1 or 2
(3) RS232 PARITY:
Parity mode: NONE / EVEN / ODD
(4) RS232 DATA BIT:
Number of data bits: 8 or 7
(5) RS485 BAUD RATE:
RS-485 interface transmission speed. 1200, 2400, 4800,
9600, 19200 and 3840 baud can be selected.
Default setting: 9600 baud
(6) RS485 STOP BIT:
Number of stop bits: 1 or 2
(7) RS485 PARITY:
Parity mode: NONE / EVEN / ODD
(8) RS485 DATA BIT:
Number of data bits: 8 or 7
(9) RS232/RS485 ID:
RS232/RS485 address. Addressable range:
1~255.
This
address
complies
with
the device number for remote
control through keyboards EKB 500, KS KBK and KS KBJ
(DEVICE
No.).
(10) PTZ-PROTOCOL:
Protocol type setting for network telemetry control,
available
protocols:
EVERFOCUS1 (EPTZ1800 Dome),
EVERFOCUS2
(EPTZ1000/3000
Dome),
ED2200/2250 (complies with Samsung protocol
SCC-641/643),
Pelco-D,
Pelco-P
NOTE:
Standard setting for EKB500 keyboard connection:
RS-485 Baud Rate
: 9600, 1 stop bit,
Parity
NONE,
RS232/RS485 ID
= Device/DVR
Nr. at keyboard
CONTROL SETUP MENU
RS232
BAUD RATE
9600 BPS
STOP BIT
1
PARITY
NONE
DATA BIT
8
RS485
BAUD RATE
9600 BPS
STOP BIT
1
PARITY
NONE
DATA BIT
8
RS232/RS485 ID
1
PTZ PROTOCOL
EVERFOCUS